72059-01R
Description
I. Model Analysis
72059: Basic model of the 7200 series preamplifier
-01: Standard version (standard input/output, standard temperature range)
R: Rack-mount version (standard full-height card)
II. Product Positioning and Usage
Function: Receives signals from the 7200 series eddy current probes (such as 72072-01), processes them into standard voltage/alarm output, and realizes radial vibration, axial displacement, temperature difference, and eccentricity monitoring.
Application: Steam turbine generators, large compressors, industrial fans, etc., for the protection of rotating machinery.
Companion: Requires the combination of 72072-01 (14mm probe) + extension cable to form a complete monitoring system.
III. Core Technical Parameters
Input: Compatible with 7200 series eddy current probes (14mm)
Sensitivity: 7.87 mV/μm (200 mV/mil)
Linear range: 2.54 mm (100 mil)
Output: -24 to 0 VDC gap voltage; relay alarm contacts
Power supply: Backplane negative pressure power supply (-24 VDC typical)
Operating temperature: 0℃ to +60℃
Structure: Full-height card (Full-size), 7200 series rack installation
Channel: Single channel (one probe input, one monitoring)
IV. Differences from Similar Models
72059-01R: Standard rack version, without key lock
72065-01K: Keyed lock version (parameter error prevention)
72072-01: Companion 14mm probe
V. Replacement and Upgrade
The 7200 series has been discontinued / phased out. The mainstream upgrade is:
3300 XL series (3300/30 preamplifier + 330104 probe)
3500 series (3500/40 monitor, four channels, more functions)