1C31110G03
May 20, 2026

1C31110G03

Brand: Emerson (Westinghouse) Model: 1C31110G03 Type: Ovation 16‑Channel 48VDC Contact Wetting High‑Speed SOE Digital Input Module Alias: 48V Contact Wetting DI Module, 16‑Point SOE Input Card, Dry Contact Monitoring Module

Description

Basic Information

  • Manufacturer: Emerson Automation Solutions

  • Series: Ovation DCS

  • Origin: United States

  • Function: Captures 16 channels of dry/wet contact signals with on‑board 48VDC contact wetting power; supports Sequence of Events (SOE) logging with 1 ms timestamp resolution for critical contact monitoring.

  • Weight: Approx. 0.6 kg

  • Status: Original new / refurbished available

  • Warranty: 12 months

Specifications

  • Channel Count: 16 single‑ended digital inputs (contact wetting)

  • Wetting Voltage: 48 VDC (on‑board auxiliary, 42–55 VDC range)

  • Input Signal Type: Dry contact / wet contact (relay, switch)

  • Logic Thresholds:

    • ON: Contact closed (senses 48VDC loop)

    • OFF: Contact open (no loop current)

  • Isolation: 1500 Vrms (channel‑to‑backplane)

  • Response Time: ≤1 ms (high‑speed)

  • SOE Resolution: 1 ms (per‑channel time stamping)

  • Operating Temp: 0°C to 60°C

  • Storage Temp: -40°C to 85°C

  • Humidity: 5%–95% non‑condensing

  • Bus Interface: Ovation I/O bus (hot‑swap capable)

  • Connector: 50‑pin edge connector (mates with 1B30035H01 / 1B30053H01‑2 bases)

Key Features

  • Integrated 48VDC contact wetting supply – no external power needed for dry contacts

  • 1 ms high‑speed response & SOE accuracy for precise contact event capture

  • 16‑point density optimized for dry contact monitoring (relays, limit switches)

  • Eliminates need for external interposing relays in contact circuits

  • LED status indicators per channel (ON/OFF) for quick visual check

  • Hot‑swap compatible (replace online without system shutdown)

  • Advanced diagnostics: open‑circuit detection, wetting voltage fault logging

  • Backward compatible with all Ovation DCS revisions

  • Industrial‑grade surge and ESD protection for harsh environments

Application Fields

  • Power generation (thermal, combined‑cycle, nuclear) – SOE for relay/switch contacts

  • Petrochemical, refining – dry contact monitoring for safety interlocks

  • Monitoring of relay contacts, limit switches, pressure switches (dry circuit)

  • Motor control centers (MCC) – contact status monitoring

  • Safety alarm systems requiring precise 1 ms event timing

  • Ovation DCS I/O cabinet expansion for dry contact input


Get a Quote