BTC06.2A-F-EN3-FW
Description
Model Explanation
BTC06: Handheld Control Unit Series
.2A: 2nd generation hardware, A-type structure (upgraded version, compared to BTC06.1A)
F: Full Function Type (with full keys + emergency stop + activation button)
EN3: Enabled (activated) Network Interface +3 = Enhanced Communication Configuration (RS232/422/485)
FW: Firmware (Firmware needs to be ordered separately)
Functions and Positioning
Used for manual operation, debugging and tool setting of Rexroth CNC / servo systems; supports point motion / incremental movement, coordinate setting, program start/stop, ratio adjustment, emergency stop safety control; with LCD display of position / speed / alarm; suitable for machine tool debugging, mold tooling, manual processing, equipment maintenance scenarios, is an upgraded version of BTC06.1A.
Core Parameters
Power Supply: DC24V (20–30V wide voltage)
Current: ≤400mA
Keyboard: 48-key polyester film keyboard (with LED)
Display: LCD 240×128 pixels, LED backlight
Processor: 68000 series microcontroller
Memory: 1MB Flash / 256KB SRAM
Interface: RS232C / RS422A / RS485 (17-pin connector)
Protection: IP65 (front), IP20 (back)
Temperature: 0°C to +55°C
Size: 315×170×57mm
Weight: Approximately 1.3kg
Safety: Dual-loop emergency stop + activation button (industrial safety standard)
Compatible Systems
Rexroth MTX CNC System (System 2000)
Rexroth DKC / HCS / CLC / DLC / MTS Servo Drive Series
Replacement for old BTA panel manual operation scenarios
Key Differences with BTC06.1A-T-NN2-FW
.2A: Second-generation hardware, more robust and stronger anti-interference
F: Full Function Type (with emergency stop + activation); 1A is T standard type
EN3: Enhanced Communication (multiple protocols); 1A is NN2 (no bus, basic keys)