5437-079
May 18, 2026

5437-079

Part Number: 5437-079 Manufacturer: Woodward, USA Product Type: 505 Series NetCon Duplex Field Terminal Module Matching System: Woodward 505 / 505E / 505H Turbine Governor & NetCon I/O System Function: Field wiring termination & signal conditioning for duplex I/O; provides 37‑pin high‑density interface between 505 CPU (5437‑076) and field sensors/actuators; ensures reliable, noise‑immune signal transmission in turbine control systems.

Description

5437-079.jpg

1. Product Overview

  • Part Number: 5437-079

  • Manufacturer: Woodward, USA

  • Product Type: 505 Series NetCon Duplex Field Terminal Module

  • Matching System: Woodward 505 / 505E / 505H Turbine Governor & NetCon I/O System

  • Function: Field wiring termination & signal conditioning for duplex I/O; provides 37‑pin high‑density interface between 505 CPU (5437‑076) and field sensors/actuators; ensures reliable, noise‑immune signal transmission in turbine control systems.

2. General Specifications

  • Supply Voltage: 24 VDC ±10% (from 5437‑077 power supply)

  • Termination: 37‑pin D‑sub + screw terminals (duplex)

  • Mounting: DIN rail / panel mount

  • Protection Class: IP20

  • Operating Temperature: -40 ℃ to +70 ℃

  • Storage Temperature: -45 ℃ to +85 ℃

  • Humidity: 5%–95% RH, non‑condensing

  • Vibration: 10–150 Hz, 2G continuous

  • Weight: Approx. 0.24 kg

  • Certifications: CE, UL, Class 1 Div 2

  • Warranty: 12 months

3. Electrical Parameters

  • Isolation: 1500 VDC field‑side isolation

  • Signal Compatibility:

    • Digital: 24 VDC sink/source, 500 mA max per channel

    • Analog: 4–20 mA / 0–10 VDC, 12‑bit resolution

  • Common‑Mode Rejection: ≥60 dB @ 50/60 Hz

  • Surge Protection: TVS diodes on all field lines

  • Backplane Interface: High‑speed serial link to 505 CPU

4. Key Features

  • Duplex (redundant) field termination for critical I/O signals

  • 37‑pin high‑density connector + screw terminals for easy field wiring

  • Built‑in signal conditioning, filtering, and surge protection

  • Full electrical isolation between controller and field wiring

  • Compact, rugged design for harsh industrial environments

  • Seamless integration with 505 CPU (5437‑076) and power supply (5437‑077)

  • Supports redundant I/O architectures for maximum system reliability

5. Typical Applications

  • Field wiring interface for Woodward 505 turbine governor systems

  • Redundant termination for critical speed, pressure, and temperature sensors

  • Isolated connection for hydraulic/electric actuator control signals

  • I/O signal conditioning in power plant and petrochemical turbine control panels

  • NetCon system expansion for large turbine‑compressor units


Get a Quote