SCHNEIDER P7330A0B0B0E0A0A POWERLOGIC ION7330 Power Quality Meter Description
Description
SCHNEIDER P7330A0B0B0E0A0A POWERLOGIC ION7330 Power Quality Meter Description
Overview
The SCHNEIDER P7330A0B0B0E0A0A POWERLOGIC ION7330 is a high-precision power quality meter designed for three-phase distribution feeders and critical load monitoring. This power quality meter performs multi-parameter electrical measurement and harmonic analysis, and the power quality meter stores historical trending and time-stamped event records for energy auditing and power quality troubleshooting. It adopts panel mounting structure and supports multiple communication protocols to connect with SCADA and energy management platforms.
Features
The SCHNEIDER P7330A0B0B0E0A0A POWERLOGIC ION7330 delivers reliable energy metering with 0.5S revenue grade accuracy for active, reactive and apparent energy. The energy metering supports four-quadrant bidirectional calculation and time-of-use tariff recording, and the energy metering data can be uploaded remotely for cost allocation and demand control. It provides harmonic measurement up to 15th order, voltage dip and swell capture, plus 32-channel historical log storage. Dual RS-485 ports and optional Ethernet web server enable flexible networking, and alarm setpoints support automatic email notification. Built-in digital inputs collect breaker status and pulse signals for auxiliary load tracking. Password protection and anti-tamper design secure metering data from unauthorized modification.
Technical Parameters
The SCHNEIDER P7330A0B0B0E0A0A POWERLOGIC ION7330 accepts auxiliary power from 95-240VAC or 120-310VDC, compatible with 50Hz and 60Hz power systems. Its rated current input is 5A via external current transformers, and voltage measurement covers common three-phase distribution levels. The operating temperature ranges from -20℃ to +60℃, non-condensing humidity 5% to 95%. It supports Modbus RTU, Modbus TCP and DNP3.0 protocols, and the backlit local LCD display shows real-time electrical values for on-site verification. All measurement functions comply with IEC and ANSI metering standards.
Working Principle
Voltage and current signals from instrument transformers enter the SCHNEIDER P7330A0B0B0E0A0A POWERLOGIC ION7330. High-speed sampling circuit converts analog signals into digital data, and the internal processor calculates power, energy, power factor and harmonic components. The whole monitoring process depends on accurate event logging, and the event logging marks every abnormal condition and state change with high-resolution timestamps. Comprehensive event logging helps engineers locate the root cause of power disturbances quickly.
Application Fields
The SCHNEIDER P7330A0B0B0E0A0A POWERLOGIC ION7330 is widely used in data centers, manufacturing plants, commercial buildings, water treatment and petrochemical facilities. It is applied for main incoming feeder monitoring, sub-metering, power quality analysis and load management in low and medium voltage distribution systems.
Get a Quote