ENDRESS+HAUSER FTL325N-H3A3 Nivotester Level Switching Unit Description
November 23, 2026

ENDRESS+HAUSER FTL325N-H3A3 Nivotester Level Switching Unit Description

ENDRESS+HAUSER FTL325N-H3A3 Nivotester level switching unit for Nivotester signal conversion and relay output

Description

ENDRESS+HAUSER FTL325N-H3A3 Nivotester Level Switching Unit Description

Overview

ENDRESS+HAUSER FTL325N-H3A3 is a Nivotester level switching unit for Liquiphant vibronic point level sensors with NAMUR signal interface. This Nivotester level switching unit receives vibration frequency signals from tuning fork sensors and converts level status into relay switching outputs for tank overfill protection and dry-run prevention. ENDRESS+HAUSER FTL325N-H3A3 supports intrinsically safe Ex ia circuit and meets SIL2 functional safety standard, and it delivers reliable Nivotester signal conversion, stable Nivotester relay output and convenient Nivotester unit replacement for liquid tank process measurement systems.

Features

ENDRESS+HAUSER FTL325N-H3A3 Nivotester level switching unit adopts DIN rail compact housing and pluggable terminal blocks for fast wiring. It monitors the resonant frequency of connected tuning fork probe and judges whether liquid reaches the detection point. The built-in line fault diagnosis circuit detects sensor wire breakage or short circuit automatically for safety backup. It supports multi-channel configuration for high/low two-point level control and carries international explosion protection approvals for hazardous area installation. Its slim structure supports quick Nivotester unit replacement, and the unit maintains consistent Nivotester signal conversion and accurate Nivotester relay output under continuous process operation.

Technical Parameters

ENDRESS+HAUSER FTL325N-H3A3 Nivotester level switching unit works with Liquiphant tuning fork sensors with NAMUR electronic insert. It provides galvanic isolation between the field hazardous side and control cabinet side, and the relay contacts are rated for safety interlock circuits. It supports 24V AC/DC or 230V AC supply options, and it complies with IEC 61508 SIL2 safety requirements for overfill protection. It supports sustained Nivotester signal conversion, real-time Nivotester relay output and straightforward Nivotester unit replacement during instrument maintenance and calibration.

Working Principle

Vibration signals generated by the tuning fork probe are transmitted to ENDRESS+HAUSER FTL325N-H3A3 Nivotester level switching unit. The internal circuit tracks resonant frequency change: when liquid covers the fork, vibration frequency shifts and triggers the relay to switch state. The relay output sends on-off level signal to PLC or safety relay for pump interlock and tank shut-off control. The fault monitoring circuit raises an alarm if sensor circuit failure occurs. Technicians can perform Nivotester unit replacement once internal circuit aging appears to resume normal Nivotester signal conversion and Nivotester relay output.

Application Fields

ENDRESS+HAUSER FTL325N-H3A3 is widely used in chemical tanks, oil storage vessels, wastewater treatment and marine process systems. It is mainly used for high-level overfill protection and low-level pump dry-run protection of liquid media. This Nivotester level switching unit ensures dependable Nivotester signal conversion, stable Nivotester relay output and easy Nivotester unit replacement for process safety instrumentation upgrade and spare part stocking.


Get a Quote