Emerson Ovation 5A26129G01 Redundant Power Supply Module
June 11, 2026

Emerson Ovation 5A26129G01 Redundant Power Supply Module

The 5A26129G01 is an original rack-mounted regulated redundant power supply module dedicated to the Emerson Ovation DCS system; suffix G01 represents its fixed hardware revision and factory full-load calibrated version. It converts cabinet input AC power into stable DC operating power for rack backplanes, DPU controllers, various I/O electronic modules and terminal bases. The module supports dual redundant parallel hot backup operation, integrates multi-layer power protection and fault self-diagnosis circuits, allows online hot-swap replacement without powering down the control cabinet, and features high efficiency, low ripple and strong anti-interference capability. It is the core power distribution unit of Ovation control cabinets, widely used in thermal power, petrochemical and metallurgical process industries.

Description

1. Overview

This power supply adopts standard Ovation rack plug-in structure, compatible with system standard rack slots. It receives AC mains input, performs rectification, filtering, isolation and DC stabilization, and outputs qualified DC working voltage to the entire rack backplane bus. Dual identical power supply modules can be configured in parallel redundant mode: the two units share the load evenly in normal operation; if one unit fails, the other automatically undertakes full load power supply without interruption of cabinet control power. Each module undergoes factory long-term full-load aging testing, output precision calibration and insulation safety testing to guarantee continuous reliable power supply for the whole control cabinet.

2. Core Functional Features

2.1 Redundant Parallel Hot Backup & Bumpless Switchover

Supports two modules hot parallel redundant configuration. Load is shared equally under normal operating conditions; upon failure, overload or abnormal shutdown of one power supply, the standby unit seamlessly takes over full load instantly, with no power dip or interruption to DPU and I/O modules, ensuring uninterrupted system control.

2.2 High Efficiency Isolated DC Stabilized Output

Adopts high-frequency switching power supply topology, high conversion efficiency, low output voltage ripple and noise; built-in isolation transformer isolates input AC side and DC output side, effectively blocking mains grid interference from coupling into the DCS internal control circuit.

2.3 Multi-level Comprehensive Safety Protection

Integrates input overvoltage/undervoltage protection, output overcurrent limiting, short-circuit automatic locking, over-temperature shutdown and reverse connection protection. Faulty module locks output automatically without impacting the other redundant power supply and the entire rack load; automatic recovery after fault removal.

2.4 Online Hot-Swap Maintenance

Under redundant configuration, a single faulty power module can be pulled out and replaced live while the cabinet remains energized; no cabinet power cut is needed, control logic and field control loops keep continuous operation, greatly reducing maintenance outage duration.

2.5 Real-time Status Monitoring & Fault Upload

Onboard power monitoring circuit collects input voltage, output voltage, output current, internal temperature and module running status; fault signals can be uploaded to the DPU and upper monitoring system via backplane bus for remote alarm and fault diagnosis.

2.6 Low Heat Generation & Cabinet Adaptability

Optimized thermal design with built-in intelligent temperature-controlled cooling; low heat emission under rated load, suitable for long-term closed cabinet continuous operation, conforming to power plant control cabinet environmental requirements.

2.7 Native System Compatibility

Fully matched with all Ovation standard racks, backplanes, DPUs and I/O series modules; no adapter board or cabinet modification required for installation, applicable for new project cabinet assembly and spare part replacement during old unit renovation.

3. Key Technical Specifications

  • Mounting Mode: Standard Ovation rack plug-in installation

  • Input: Industrial AC mains wide-range input

  • Output: Regulated DC working power for rack backplane

  • Redundancy Mode: Dual modules parallel hot redundant, automatic load sharing & bumpless switchover

  • Protection Functions: Input over/under voltage, output overcurrent, short-circuit lockout, overtemperature protection

  • Isolation: Input-output reinforced electrical isolation

  • Operating Temperature: 0 ℃ ~ +60 ℃

  • Storage & Transportation Temperature: −40 ℃ ~ +85 ℃

  • Relative Humidity: ≤95% RH, non-condensing

  • EMC Compliance: Complies with industrial G3 anti-corrosion standard and power plant cabinet anti-interference requirements

  • Hot-Swap Condition: Only allows single module hot swap under dual redundant running state

4. Front Panel LED Indicator Definition

  1. INPUT (Green): Steady ON = AC input power normal; OFF = no input or input abnormal

  2. OUT OK (Green): Steady ON = DC output stable and loaded normally

  3. FAULT (Red): Lights up for overcurrent, short circuit, overtemperature or internal hardware failure; fault status latched

  4. REDUND (Green): Illuminated when redundant partner module is online and synchronized normally

5. Application Scope

  1. Thermal Power Industry

    Serves as the core power supply for boiler, turbine, generator main control cabinets and auxiliary system control cabinets, providing stable working power for DPUs, I/O modules and terminal bases to guarantee unit automatic control uninterrupted operation.

  2. Petrochemical Industry

    Equipped in reactor, fractionator and compression unit control cabinets, realizing redundant reliable power supply for process control systems and avoiding production shutdown caused by single power supply failure.

  3. Metallurgy, Waste Incineration Power Plants & District Heating Stations

    Provides redundant stable DC power for full-set automation control cabinets, supporting long-cycle unattended continuous running of production lines.