5200D85 Standard 8-Slot General Industrial I/O Subrack Backplane (Common Q Class 1E Nuclear DCS)
Description
Parameter Specifications
Part Number: 5200D85
Manufacturer: Emerson Westinghouse
Applicable System: Common Q Class 1E Nuclear Safety DCS
Matching Equipment
Max load: 8 slots standard 4D33xxx series I/O terminal daughter cards
Redundant power supply: 475HP1ENA9GMT
Mainframe master communication backplane
PCB Material: Multi-layer thick copper zero-halogen V-0 flame retardant high-Tg FR-4
Mechanical Size: Standard 6U industrial subrack, depth matched to 145mm I/O daughter card
Ambient Operating Conditions
Operating Temperature: -25℃ ~ +70℃
Storage Temperature: -50℃ ~ +125℃
Humidity: 5%–95% RH, non-condensing
Power Distribution Index
Dual redundant DC12V / DC24V power input
Single slot rated output power: 30W
Independent overcurrent protection fuse for each slot
Hot-swap soft-start circuit per slot to suppress plug surge current
Bus & Signal Design
Isolated safety parallel signal bus + independent power bus + fault alarm bus
Each slot integrated EMI filter to eliminate inter-slot signal crosstalk
Slot connector gold plating thickness: 3μm anti-wear gold plating
Isolation & EMC Performance
Inter-slot signal isolation: 1500V AC
Power bus dielectric withstand: 2000V AC / 60s
Power frequency interference attenuation ≥40dB, comply with nuclear standard EMC screening
Mechanical Reliability
Continuous vibration resistance: 8g (10–150Hz)
Shock resistance: 25g pulse, 11ms duration
Reinforced metal fixed bracket, anti-loose installation structure
Core Features
8-slot universal I/O subrack backplane; full hot-swap support; independent single-slot fault isolation; full compatibility with all G-version standard 4D33xxx I/O daughter modules; cost-effective general industrial cabinet solution.
Certifications: CE, UL508, IEC60204-1, NRC Class 1E nuclear safety qualification
Aging Test Standard: 72h full-load high-low temperature cyclic aging + electromagnetic stress screening
Design Service Life: ≥100,000 hours continuous 24/7 operation
Warranty Period: 12-month global warranty for original and factory refurbished backplanes
Application Fields
Nuclear Power Plant Common Q Safety Control Cabinets
Standard 8-slot I/O subrack for normal heat-dissipation reactor auxiliary cabinets, mixed installation of analog input, RTD, thermocouple, digital input/output and pulse encoder modules for primary coolant, steam generator and containment conventional parameter monitoring.
AP1000 Post-Accident Monitoring System (PAMS)
Deployed in normal temperature containment peripheral equipment rooms, carrying passive cooling system pressure, flow, temperature acquisition modules and accident state digital feedback I/O cards.
Thermal & Hydropower Station Main Control Cabinets
8-slot universal subrack for boiler, turbine normal temperature control cabinets, equipped with pressure/liquid level analog modules, bearing temperature RTD and valve feedback DI modules.
Explosion-Proof Petrochemical Process Control Cabinets
General industrial backplane for reaction tank, pipeline normal temperature hazardous zone cabinets, compatible with process AI, safety interlock DI/DO daughter cards.
Offshore Oil & Gas Platform Process Cabinets
Standard subrack for platform medium temperature control cabinets, matched with flow pulse transmitters and pressure analog acquisition modules.
Nuclear Island Backup Diesel Generator Control Cabinets
Carry exhaust temperature thermocouple, crankshaft speed encoder and safety trip interlock DI/DO modules.
5200D Series Model Coding & Version Distinction
1. Model digit rule
5200D04:4-slot backplane
5200D06:6-slot base model (G01 standard / H01 high-temp)
5200D85:8-slot general industrial base model (no suffix = standard G version)
5200D08:8-slot high-end reinforced variant (seismic enhanced)
2. Suffix version definition
No suffix / Gxx: General industrial standard, operating temp -25~+70℃
Hxx: High-temperature enhanced variant, upper limit +80℃, anti-oxidation conformal coating, thermal aging screening (e.g. 5200D06H01)
3. Product line division
4D33xxx: Front-end field signal I/O terminal daughter cards (AI/AO/DI/DO/Temp/Pulse/Encoder)
5200Dxxx: Subrack backplane rack accessories, power distribution + bus interconnection + mechanical carrier for I/O modules
Core Difference: 5200D85 vs High-Temp H-series (5200D06H01)
Temperature resistance: 5200D85 standard up to +70℃; H-suffix high-temp version up to +80℃ for near-primary high-heat cabinets
PCB coating: 5200D85 standard single-layer protective coating; H version triple anti-oxidation/anti-mold/salt-fog conformal coating
Connector gold plating: 5200D85 3μm standard gold; H version 5μm high-temperature wear-resistant thick gold
Component screening: 5200D85 conventional aging test; H version extended 144h high-temperature thermal soak screening
Applicable scenarios: 5200D85 for normal heat-dissipation general cabinets; H-suffix for containment wall, primary equipment adjacent poorly ventilated high-temperature cabinets
Get a Quote