4D33934G01 Standard 8-Channel Isolated Pulse/Frequency Counter Terminal Daughter Card for Common Q Class 1E Nuclear Safety DCS
Description
Parameter Specifications
Part Number: 4D33934G01
Manufacturer: Emerson Westinghouse
Compatible System: Common Q Class 1E Safety Instrument & Control DCS System
Matching Accessories: Pulse/Frequency master acquisition boards, 49E-3649 rack backplane 49E-3649, redundant rack power supply 475HP1ENA9GMT
PCB Material: Multi-layer isolated V-0 flame-retardant high-Tg FR-4 substrate
Dimension & Weight: 145mm × 66mm × 20.6mm; Net weight: 62g
Ambient Operating Envelope
Operating Temp: -25℃ ~ +70℃
Storage Temp: -50℃ ~ +125℃
Humidity: 5%–95% RH, non-condensing
Power Supply: DC 12V / DC 24V dual adaptive wide-range input
Input Channels: 8 fully independent galvanic isolated pulse/frequency counter channels
Supported Signal Types
NPN/PNP active pulse signal 0–24VDC
Sine wave / square wave frequency signal
Pulse frequency range: 0.01Hz ~ 100kHz
Pulse counting range: 0 ~ 999,999,999 32-bit cumulative count
Signal amplitude threshold: Low ≤6V DC, High ≥18V DC
Isolation Performance
Channel-to-backplane isolation: 1500V AC
Dielectric withstand: 2000V AC / 60s
Insulation resistance: ≥1200MΩ @ 500VDC
EMC Anti-interference Performance
Power frequency interference attenuation ≥40dB, fully compliant with IEC 61000-6-2 industrial EMC standard
Protection & Intelligent Diagnosis Functions
Per-channel input overcurrent limiting protection
Bidirectional TVS high-energy surge absorption circuit
Reverse wiring polarity lockout anti-damage protection
Real-time full fault detection: signal open-circuit, short-circuit, frequency out-of-range, signal amplitude abnormal, sensor power loss
Time-stamped fault status + channel number + fault classification uploaded to master controller
Mechanical Reliability
Continuous vibration resistance: 8g (10–150Hz)
Shock resistance: 25g pulse, duration 11ms
Core Feature: Single module hot swappable under energized rack without interrupting safety pulse/frequency measurement loops
Certifications: CE, UL508, IEC60204-1, NRC Class 1E nuclear safety qualification
Aging Validation Standard: 72-hour full-load high-low temperature cyclic aging test + frequency precision calibration screening
Design Service Life: ≥100,000 hours of 24/7 unattended continuous operation
Warranty Period: 12-month global unified warranty for original factory modules and certified factory refurbished modules
Application Fields
Nuclear Power Plant Common Q Safety I&C Racks
Dedicated multi-channel pulse/frequency acquisition terminal for reactor auxiliary safety cabinets, collecting main coolant flow pulse transmitters, primary pump rotational speed probes and chemical volumetric dosing pulse meter signals for flow totalization and overspeed trip interlock.
AP1000 Nuclear Post-Accident Monitoring System (PAMS)
Isolated pulse counter board for containment passive cooling flow pulse sensors, emergency pump speed encoders and post-accident medium flow cumulative measurement.
Thermal & Hydropower Station Main Control Systems
Dedicated frequency input module for turbine speed probes, feedwater flow pulse transmitters and generator cooling fan rotational speed monitoring.
High-Risk Explosion-Proof Petrochemical DCS Distributed Control System
Special pulse signal terminal card for process flow pulse meters, agitator speed encoders and high-pressure pump speed sensors in hazardous explosion zones.
Offshore Oil & Gas Explosion-Proof Automation Racks
Isolation frequency acquisition interface for crude pipeline flow pulse transmitters, separator pump speed probes and marine platform chemical dosing pulse meters.
Large Diesel Generator Safety Sequential Control Cabinets
Multi-point pulse input subcard for genset crankshaft speed sensors, cooling water flow pulse meters and fuel metering pulse transmitters for overspeed protection.
Municipal Large-Scale Water Treatment Safety Interlock DCS Systems
High-precision isolated pulse terminal for main water pipeline flow pulse meters, sludge pump speed encoders and chemical dosing flow cumulative measurement.
Metallurgy & Cement Kiln Production Lines
Dedicated high-frequency pulse acquisition module for kiln exhaust gas flow pulse transmitters, raw material feeding speed encoders and cooling fan rotational speed monitoring probes.
Series Unified Iteration Rule (Consistent with full Common Q I/O board product line)
G01: Standard basic industrial version, 1500V isolation, 40dB EMI attenuation, basic signal fault alarm, no waveform storage
G02: Reinforced industrial enhanced version, 1800V isolation, 45dB attenuation, optimized high-speed frequency filtering, fast signal drift diagnosis
G03: Gen3 nuclear high-isolation grade, 2000V isolation, 50dB attenuation, fault waveform capture + non-volatile historical fault storage
G04: Gen4 flagship ultra-high isolation, 2200V isolation, 55dB attenuation, nanosecond high-precision timestamp, expanded operating temperature range
G05: Gen5 premium seismic qualified grade, 2500V isolation, 60dB attenuation, anti-loose locking terminal structure, full IEEE 344 seismic certification, extended service life & warranty
G06: Gen6 extreme super-isolation flagship, 3000V isolation, 65dB attenuation, nuclear anti-radiation component screening, double anti-loose terminals, 15-year power-off fault data retention, full seismic & radiation dual certification
Get a Quote