4D33916G01 Standard 16-Channel Isolated Sourcing Active Discrete Output Terminal Daughter Card for Common Q Class 1E Nuclear Safety DCS
June 10, 2026

4D33916G01 Standard 16-Channel Isolated Sourcing Active Discrete Output Terminal Daughter Card for Common Q Class 1E Nuclear Safety DCS

NRC Class 1E nuclear safety certified, the 4D33916G01 is a high-density standard isolated sourcing-type active digital output terminal daughter card developed exclusively for Emerson Westinghouse Common Q nuclear safety I&C platform. It converts digital safety logic commands from master logic controllers into isolated 24VDC sourcing active switch signals, used to drive nuclear safety field loads including safety relay coils, solenoid pilot valves, trip amplifier enable inputs, fault indicator lamps and interlock trigger solid-state circuits inside nuclear auxiliary safety systems.

Description

Parameter Specifications

  1. Part Number: 4D33916G01

  2. Manufacturer: Emerson Westinghouse

  3. Compatible System: Common Q Class 1E Safety Instrument & Control DCS System

  4. Matching Accessories: Sourcing discrete output master logic boards, 49E-3649 rack backplane, 475HP1ENA9GMT redundant rack power supply

  5. PCB Material: Multi-layer isolated V-0 flame-retardant high-Tg FR-4 substrate

  6. Dimension & Weight: 145mm × 66mm × 20.6mm; Net weight: 63g

  7. Ambient Operating Envelope

    Operating Temp: -25℃ ~ +70℃

    Storage Temp: -50℃ ~ +125℃

    Humidity: 5%–95% RH, non-condensing

  8. Power Supply: DC 12V / DC 24V dual adaptive wide-range input

  9. Output Channels: 16 fully independent galvanic isolated sourcing discrete output channels

  10. Drive Type: 24VDC sourcing output (source positive voltage to load, load negative connected to field ground)

  11. Channel Load Capacity

    Continuous rated output current per channel: 0.5A

    Instant peak withstand current: 0.8A

    Max withstand load inductive kickback voltage: ±40VDC

  12. Isolation Performance

    Channel-to-backplane isolation: 1500V AC

    Dielectric withstand: 2000V AC / 60s

    Insulation resistance: ≥1200MΩ @ 500VDC

  13. EMC Index: Power frequency interference attenuation ≥40dB, fully compliant with IEC 61000-6-2 industrial EMC standard

  14. Protection & Intelligent Diagnosis Functions

    Per-channel precise constant current limiting protection

    Bidirectional TVS high-energy surge absorption circuit for inductive load kickback suppression

    Reverse wiring polarity lockout anti-damage protection

    Real-time detection of output loop open-circuit / short-circuit / overload overcurrent fault

    Time-stamped fault status + channel number uploaded to master controller

  15. Mechanical Reliability

    Continuous vibration resistance: 8g (10–150Hz)

    Shock resistance: 25g pulse, duration 11ms

  16. Core Feature: Single module hot swappable under energized rack without interrupting safety interlock drive loops

  17. Certifications: CE, UL508, IEC60204-1, NRC Class 1E nuclear safety qualification

  18. Aging Validation Standard: 72-hour full-load high-low temperature cyclic aging test

  19. Design Service Life: ≥100,000 hours of 24/7 unattended continuous operation

  20. Warranty Period: 12-month global unified warranty for original & factory refurbished modules

Application Fields

  1. Nuclear Power Plant Common Q Safety I&C Racks

    High-density multi-point sourcing active drive terminal for reactor auxiliary cabinets, outputting 24VDC sourcing signals to batches of safety interlock relay coils, small pilot isolation solenoid valves and fault status indicator lamps.

  2. AP1000 Nuclear Post-Accident Monitoring System (PAMS)

    Isolated multi-channel sourcing digital output board for containment accident status indicator lights, passive cooling auxiliary pilot valves and post-accident interlock trigger relays.

  3. Thermal & Hydropower Station Main Control Systems

    High-density sourcing DO module for boiler safety alarm lamps, auxiliary isolation solenoid valves and turbine protection interlock relay coils.

  4. High-Risk Explosion-Proof Petrochemical DCS Distributed Control System

    Field high-density sourcing drive wiring card for reactor safety alarm indicators, auxiliary ESD pilot solenoids and zone safety interlock relays in hazardous areas.

  5. Offshore Oil & Gas Explosion-Proof Automation Racks

    Isolation multi-channel sourcing drive interface for platform safety warning lights, wellhead auxiliary pilot solenoid valves and separator protection interlock relays.

  6. Large Diesel Generator Safety Sequential Control Cabinets

    Multi-point sourcing discrete output subcard for genset fault alarm lamps, cooling water bypass pilot solenoids and overspeed protection interlock relay coils.

  7. Municipal Large-Scale Water Treatment Safety Interlock DCS Systems

    High-density isolation sourcing drive terminal for pipeline fault warning lamps, emergency isolation pilot valves and chemical dosing system interlock relays.

  8. Metallurgy & Cement Kiln Production Lines

    Multi-channel sourcing drive module for kiln safety alarm indicators, flue gas auxiliary isolation solenoids and raw material feeding protection interlock relays.

Series Iteration Rule (Unified with all Common Q I/O Terminal Boards)

  • G01: Standard basic industrial version, 1500V isolation, 40dB EMI attenuation, basic loop protection & simple fault alarm

  • G02: Reinforced industrial enhanced version, 1800V isolation, 45dB attenuation, upgraded fast overload/short-circuit fault diagnosis

  • G03: Gen3 nuclear high-isolation grade, 2000V isolation, 50dB attenuation, fault waveform capture + non-volatile historical fault storage

  • G04: Gen4 flagship ultra-high isolation, 2200V isolation, 55dB attenuation, nanosecond high-precision timestamp, expanded operating temperature range

  • G05: Gen5 premium seismic qualified grade, 2500V isolation, 60dB attenuation, anti-loose locking terminal structure, full IEEE 344 seismic certification, extended service life & warranty

  • G06: Gen6 extreme super-isolation flagship, 3000V isolation, 65dB attenuation, nuclear anti-radiation component screening, double anti-loose terminals, 15-year power-off fault data retention, full seismic & radiation dual certification


Get a Quote