4D33914G02 Reinforced Industrial Enhanced 16-Channel Isolated Discrete Input Terminal Daughter Card for Common Q Class 1E Nuclear Safety DCS
Description
Parameter Specifications
Part Number: 4D33914G02
Manufacturer: Emerson Westinghouse
Compatible System: Common Q Class 1E Safety Instrument & Control DCS System
Matching Accessories: Discrete input master logic boards, 49E-3649 rack backplane, 475HP1ENA9GMT redundant rack power supply
PCB Material: Multi-layer thick copper zero-halogen V-0 flame-retardant high-Tg FR-4
Dimension & Weight: 145mm × 66mm × 20.6mm; Net Weight: 64g
Ambient Operating Envelope
Operating Temp: -25℃ ~ +70℃
Storage Temp: -50℃ ~ +125℃
Humidity: 5%–95% RH, non-condensing
Power Supply: DC 12V / DC 24V dual wide-range adaptive input
Input Channels: 16 fully independent galvanic isolated discrete input channels
Signal Type: Passive dry contact DI (no external power required for field contacts)
Contact judgment threshold: ON contact resistance ≤500Ω; OFF contact resistance ≥100kΩ
Isolation Index
Single channel 1800V AC isolation withstand; 2000V AC dielectric strength test for 60s; Insulation resistance ≥1200MΩ @500VDC
EMC Anti-interference Performance
Power frequency interference attenuation ≥45dB, fully compliant with IEC 61000-6-2 industrial EMC specification
Protection & Intelligent Diagnosis Functions
Per-channel precise current limiting protection
Bidirectional high-energy surge absorption circuit
Reverse wiring polarity lockout & misconnection anti-damage protection
Real-time fast detection: contact open-circuit, short-circuit, contact bounce, abnormal contact resistance, terminal loose fault
High-precision time-stamped fault code + channel location real-time upload to master controller
Mechanical Reliability
Continuous vibration resistance 8g (10–150Hz); Shock resistance 25g pulse, 11ms duration
Core Feature: Single module hot swappable under energized rack without interrupting safety interlock signal acquisition loops
Certifications: CE, UL508, IEC60204-1, NRC Class 1E nuclear safety qualification
Aging Validation Standard: 72-hour full-load high-low temperature cyclic aging test
Design Service Life: ≥100,000 hours of 24/7 unattended continuous operation
Warranty Period: 12-month global unified warranty for original factory modules and certified factory refurbished modules
Application Fields
Nuclear Power Plant Common Q Safety I&C Racks
Reinforced high-density multi-point digital signal acquisition terminal for reactor auxiliary cabinets, centralized collection of isolation valve feedback switches, safety equipment interlock contacts and primary trip protection dry contact signals.
AP1000 Nuclear Post-Accident Monitoring System (PAMS)
High anti-interference isolated digital input board for containment multi-group accident status feedback contacts, passive cooling valve position limit switches and containment barrier interlock switches.
Thermal & Hydropower Station Main Control Systems
Upgraded high-density DI input module for boiler safety door interlocks, turbine trip limit switches, feedwater valve position feedback and fire protection interlock contacts.
High-Risk Explosion-Proof Petrochemical DCS Distributed Control System
Premium reinforced digital wiring terminal card for reactor emergency shutdown interlock contacts, safety barrier door switches and storage tank over-limit trip dry contacts in hazardous zones.
Offshore Oil & Gas Explosion-Proof Automation Racks
Anti-vibration isolation digital acquisition interface for wellhead ESD valve feedback switches, platform safety hatch interlocks and separator high-pressure trip contacts.
Large Diesel Generator Safety Sequential Control Cabinets
Multi-point discrete input subcard for unit overspeed trip switches, cooling water low-pressure interlock contacts and exhaust over-temperature protection limit switches.
Municipal Large-Scale Water Treatment Safety Interlock DCS Systems
Reinforced isolation digital signal terminal for pipeline emergency gate feedback switches, chemical tank overflow interlock contacts and blower fault trip limit switches.
Metallurgy & Cement Kiln Production Lines
High-reliability multi-point digital acquisition module for kiln safety door interlock contacts, dust removal equipment fault switches and high-temperature pipeline over-limit trip dry contacts.
Core Upgrade Difference: G02 vs Base G01
Channel isolation voltage upgraded from 1500V AC to 1800V AC, greatly reduce inter-channel signal crosstalk
EMI filter stage optimized, power frequency interference attenuation improved from 40dB to 45dB, stronger anti-electromagnetic interference ability in nuclear island
Optimized contact resistance real-time monitoring logic, support contact bounce and poor contact early warning, improve fault detection speed
Reinforced PCB copper thickness and terminal anti-corrosion passivation coating, adapt to long-term high humidity nuclear plant environment
Surge absorption circuit upgraded to dual-stage design, stronger resistance to field switching impact and lightning transient noise
Fully consistent mechanical size, backplane pin definition and signal logic with G01, support direct plug-and-play replacement without rack modification
4D33914 Series Unified Iteration Rule (Consistent with full Common Q I/O product line)
G01: Standard basic version, 1500V isolation, 40dB attenuation, basic contact status detection, simple fault alarm
G02: Reinforced industrial enhanced version, 1800V isolation, 45dB attenuation, fast multi-dimensional contact fault diagnosis
G03: Gen3 nuclear high-isolation grade, 2000V isolation, 50dB attenuation, fault waveform capture + non-volatile historical fault storage
G04: Gen4 flagship ultra-high isolation, 2200V isolation, 55dB attenuation, nanosecond high-precision timestamp, expanded operating temperature range
G05: Gen5 premium seismic qualified grade, 2500V isolation, 60dB attenuation, anti-loose locking terminals, IEEE 344 seismic certification, extended service life & warranty
G06: Gen6 extreme super-isolation flagship, 3000V isolation, 65dB attenuation, nuclear anti-radiation screening, double anti-loose terminals, 15-year power-off fault data retention, full seismic + radiation dual certification
Get a Quote