4D33913G01 Standard 16-Channel Isolated Analog Output Terminal Daughter Card for Common Q Class 1E Nuclear Safety DCS
Description
Parameter Specifications
Part Number: 4D33913G01
Manufacturer: Emerson Westinghouse
Compatible System: Common Q Class 1E Safety Instrument & Control DCS System
Matching Accessories: Analog output master control boards, 49E-3649 rack backplane, 475HP1ENA9GMT redundant rack power supply
PCB Material: Multi-layer isolated V-0 flame-retardant high-Tg FR-4 substrate
Dimension & Weight: 145mm × 66mm × 20.6mm; Net weight: 63g
Ambient Operating Envelope
Operating Temp: -25℃ ~ +70℃
Storage Temp: -50℃ ~ +125℃
Humidity: 5%–95% RH, non-condensing
Power Supply: DC 12V / DC 24V dual adaptive wide-range input
Output Channels: 16 fully independent galvanic isolated analog output channels
Standard Output Signal Range
Current output: 4–20mA DC (loop powered passive valve positioners)
Voltage output: 0–10V DC (direct drive small actuators, VFD speed setpoint)
Load Capacity
4–20mA current output: Max load resistance 750Ω per channel
0–10V voltage output: Min load impedance ≥10kΩ per channel
Isolation Performance
Channel-to-backplane isolation: 1500V AC
Dielectric withstand: 2000V AC / 60s
Insulation resistance: ≥1200MΩ @ 500VDC
EMC Anti-interference Performance
Power frequency interference attenuation ≥40dB, fully compliant with IEC 61000-6-2 industrial EMC standard
Protection & Intelligent Diagnosis Functions
Per-channel precise constant current limiting protection
Bidirectional TVS high-energy surge absorption circuit
Reverse wiring polarity lockout anti-damage protection
Real-time detection of analog output loop open-circuit / short-circuit / overload fault
Time-stamped fault status and channel number uploaded to master controller
Mechanical Reliability
Continuous vibration resistance: 8g (10–150Hz)
Shock resistance: 25g pulse, duration 11ms
Core Feature: Single module hot swappable under energized rack without interrupting safety closed-loop control loops
Certifications: CE, UL508, IEC60204-1, NRC Class 1E nuclear safety qualification
Aging Validation Standard: 72-hour full-load high-low temperature cyclic aging test
Design Service Life: ≥100,000 hours of 24/7 unattended continuous operation
Warranty Period: 12-month global unified warranty for original factory modules and certified factory refurbished modules
Application Fields
Nuclear Power Plant Common Q Safety I&C Racks
High-density multi-point safety analog drive terminal for reactor auxiliary cabinets, outputting regulating signals to batch cooling water control valves, containment ventilation dampers and chemical additive flow actuators.
AP1000 Nuclear Post-Accident Monitoring System (PAMS)
Isolated multi-channel analog output board for containment post-accident cooling flow adjustment valves, containment pressure relief dampers and emergency cooling fan speed regulators.
Thermal & Hydropower Station Main Control Systems
High-density AO output module for boiler feedwater regulating valves, air-fuel ratio dampers and turbine auxiliary cooling medium positioners.
High-Risk Explosion-Proof Petrochemical DCS Distributed Control System
Field high-density analog drive wiring card for reactor medium regulating valves, storage tank level adjustment actuators and heating medium flow control devices in hazardous zones.
Offshore Oil & Gas Explosion-Proof Automation Racks
Isolation multi-channel analog drive interface for wellhead manifold pressure control valves, separator liquid level actuators and platform heating medium regulators.
Large Diesel Generator Safety Sequential Control Cabinets
Multi-point analog output subcard for genset fuel flow adjustment actuators, cooling water bypass control valves and exhaust gas treatment dampers.
Municipal Large-Scale Water Treatment Safety Interlock DCS Systems
High-density isolation analog drive terminal for pipeline flow regulating valves, aeration tank oxygen control dampers and chemical dosing metering pumps.
Metallurgy & Cement Kiln Production Lines
Multi-channel analog drive module for kiln fuel flow control valves, flue gas recirculation dampers and raw material feeding speed adjustment actuators.
Series Iteration Rule Reference (Consistent with all Common Q I/O Terminal Boards)
G01: Standard basic industrial version, 1500V isolation, 40dB EMI attenuation, basic loop protection & simple fault alarm
G02: Reinforced industrial enhanced version, 1800V isolation, 45dB attenuation, upgraded real-time fault judgment
G03: Gen3 nuclear high-isolation grade, 2000V isolation, 50dB attenuation, fault waveform capture + non-volatile historical fault storage
G04: Gen4 flagship ultra-high isolation, 2200V isolation, 55dB attenuation, nanosecond high-precision timestamp, wider operating temperature range
G05: Gen5 premium seismic qualified grade, 2500V isolation, 60dB attenuation, anti-loose locking terminal structure, full IEEE 344 seismic certification, extended service life & warranty
G06: Gen6 extreme super-isolation flagship, 3000V isolation, 65dB attenuation, nuclear anti-radiation component screening, double anti-loose terminals, 15-year power-off fault data retention, full seismic & radiation dual certification
Get a Quote