4D33764G01 Standard 12-Channel Isolated RTD Temperature Input Terminal Daughter Card for Common Q Class 1E Nuclear Safety DCS
Description
Parameter Specifications
Part Number: 4D33764G01
Manufacturer: Emerson Westinghouse
Compatible System: Common Q Class 1E Safety Instrument & Control DCS System
Matching Accessories: RTD temperature master acquisition boards, 49E-3649 rack backplane, 475HP1ENA9GMT redundant rack power supply
PCB Material: Multi-layer isolated V-0 flame-retardant high-Tg FR-4
Dimension & Weight: 120mm × 66mm × 20.6mm; Net weight: 58g
Ambient Conditions: Operating temperature -25℃ ~ +70℃; Storage temperature -50℃ ~ +125℃; Humidity 5%–95% RH, non-condensing
Power Supply: DC 12V / DC 24V dual adaptive input
Input Channels: 12 fully independent galvanic isolated RTD input channels
Supported Sensor: 3-wire PT100 platinum resistance temperature detector
Standard Measurement Range: -200℃ ~ +850℃
Isolation Performance: 1500V AC isolation voltage per channel; 2000V AC dielectric withstand for 60s; Insulation resistance ≥1200MΩ @ 500VDC
EMC Index: Power frequency interference attenuation ≥40dB, compliant with IEC 61000-6-2 industrial EMC standard
Protection & Diagnosis: Per-channel current-limiting protection, bidirectional surge absorption, reverse polarity protection, sensor open/short-circuit fault detection, real-time fault status upload to main controller
Mechanical Performance: Continuous vibration resistance 8g (10–150Hz); Shock resistance 25g pulse, duration 11ms
Core Feature: Single-module hot swappable under energized rack
Certifications: CE, UL508, IEC60204-1, NRC Class 1E nuclear safety certification
Aging Test Standard: 72-hour full-load high-low temperature cyclic aging test
Design Service Life: ≥100,000 hours of 24/7 uninterrupted continuous operation
Warranty: 12-month global unified warranty
Application Fields
Nuclear power plant Common Q Class 1E safety I&C racks
Standard temperature acquisition terminal for auxiliary cabinet cooling pipeline, pump/motor bearing and containment medium PT100 temperature probes.
AP1000 nuclear Post-Accident Monitoring System (PAMS)
Isolated temperature signal conversion board for containment equipment shell, circulation pipeline and accident cooling system temperature sensors.
Thermal & hydropower station control systems
RTD input module for boiler drum wall, turbine bearing, generator stator and cooling water PT100 detectors.
Explosion-proof petrochemical DCS distributed control system
Wiring terminal for reactor wall, process pipeline medium and storage tank PT100 temperature sensors.
Offshore oil & gas explosion-proof automation racks
Signal isolation board for wellhead crude pipeline, separator equipment and heating medium PT100 probes.
Large diesel generator safety sequential control cabinets
Temperature input subcard for engine cylinder, main bearing and cooling circulation water PT100 sensors.
Municipal large-scale water treatment safety interlock DCS
Isolation terminal for sewage pipeline, aeration tank and blower bearing PT100 temperature detectors.
Metallurgy and cement kiln production lines
Temperature acquisition module for kiln shell, flue gas pipeline and raw material conveying equipment PT100 sensors.
Get a Quote