4D33676G02 Upgraded Reinforced 16-Channel Isolated Analog Input Terminal Daughter Card for Common Q Class 1E Nuclear Safety DCS
June 10, 2026

4D33676G02 Upgraded Reinforced 16-Channel Isolated Analog Input Terminal Daughter Card for Common Q Class 1E Nuclear Safety DCS

NRC Class 1E nuclear safety certified, the 4D33676G02 is the upgraded reinforced analog input terminal board improved based on standard model 4D33676G01 for Emerson Westinghouse Common Q safety I&C platform. It accurately collects standard 4–20mA DC and 0–10V DC analog signals from field pressure, flow, liquid level and temperature transmitters. Each channel adopts 1800V reinforced galvanic isolation and optimized high-order multi-stage LC EMI filters to effectively suppress power frequency noise, ground loop potential drift and lightning surge transient interference. Equipped with thickened gold-plated backplane connectors and anti-corrosion nickel alloy screw terminals, this card supports full-channel high-speed fault diagnosis, comprehensive multi-layer circuit protection and hot-swap maintenance without interrupting other signal acquisition loops, maintaining stable high-precision analog signal collection under high-temperature, high-humidity, dusty and vibration-prone harsh industrial environments.

Description

Parameter Specifications

  1. Part Number: 4D33676G02

  2. Manufacturer: Emerson Westinghouse

  3. Compatible System: Common Q Class 1E Safety Instrument & Control DCS System

  4. Matching Components: Analog input master acquisition boards, 49E-3649 rack backplane, 475HP1ENA9GMT redundant rack power supply

  5. PCB Material: Multi-layer thick copper isolated V-0 flame-retardant high-Tg FR-4

  6. Dimension & Weight: 118mm × 64.5mm × 19.7mm; Net weight: 54g

  7. Ambient Conditions: Operating temperature -25℃ ~ +70℃; Storage temperature -50℃ ~ +125℃; Humidity 5%–95% RH, non-condensing

  8. Power Input: DC 12V / DC 24V dual adaptive power supply

  9. Input Channels: 16 fully independent galvanic isolated analog input channels

  10. Supported Signal Range: 4–20mA DC current signal, 0–10V DC voltage signal

  11. Isolation Performance: 1800V AC isolation voltage per channel; 2000V AC dielectric withstand for 60s; Insulation resistance ≥1200MΩ @ 500VDC

  12. EMC Index: Power frequency interference attenuation ≥45dB, compliant with IEC 61000-6-2 industrial EMC standard

  13. Protection & Diagnosis: Per-channel precision current-limiting protection, bidirectional high-energy surge absorption, reverse polarity lockout, real-time open-circuit/short-circuit fault detection, high-precision timestamp fault code upload to main controller

  14. Mechanical Performance: Continuous vibration resistance 8g (10–150Hz); Shock resistance 25g pulse, duration 11ms

  15. Core Feature: Single-module hot swappable under energized rack

  16. Certifications: CE, UL508, IEC60204-1, NRC Class 1E nuclear safety certification

  17. Aging Test Standard: 72-hour full-load high-low temperature cyclic aging test

  18. Design Service Life: ≥100,000 hours of 24/7 uninterrupted continuous operation

  19. Warranty: 12-month global unified warranty

Application Fields

  1. Nuclear power plant Common Q Class 1E safety I&C racks: Reinforced isolation analog signal acquisition terminal for auxiliary cabinet flow, pressure, liquid level and temperature transmitters

  2. AP1000 nuclear Post-Accident Monitoring System (PAMS): High-stability isolation signal conversion board for auxiliary containment process analog transmitters

  3. Thermal & hydropower station control systems: Upgraded analog input module for boiler water flow, main steam pressure and drum water level transmitters

  4. Explosion-proof petrochemical DCS distributed control system: Anti-interference wiring card for reactor pressure, pipeline flow and storage tank liquid level analog transmitters

  5. Offshore oil & gas explosion-proof automation racks: Signal isolation interface for wellhead pressure, crude oil pipeline flow and medium temperature transmitters

  6. Large diesel generator safety sequential control cabinets: Analog input subcard for engine oil pressure, cooling water temperature and fuel flow transmitters

  7. Municipal large-scale water treatment safety interlock DCS: Reinforced isolation terminal for pipeline flow, sedimentation tank liquid level and water pressure transmitters

  8. Metallurgy and cement kiln production lines: High-precision analog signal acquisition module for kiln internal pressure, flue gas flow and raw material bin level transmitters


Get a Quote