4A07221G07 High Precision Reinforced Isolation Analog Input Terminal Daughter Card for Common Q Class 1E Nuclear Safety DCS System
Description
1. Product Title
2. Product Brief Introduction
3. Parameter Specification Sheet
Basic Information
Part Number: 4A07221G07
Brand: Emerson / Westinghouse
Product Type: High Precision Reinforced Isolation Analog Input Field Terminal Daughter Card
Compatible Platform: Common Q Class 1E Safety Instrument & Control DCS System
Matching Supporting Modules: Analog input acquisition master boards, 49E-3649 rack backplane, 475HP1ENA9GMT redundant rack power supply
PCB Material: Multi-layer isolated high Tg FR-4, V-0 flame retardant
Surface Treatment: Thick hard gold plating for backplane connectors; nickel-gold oxidation-resistant screw-type field wiring terminals
Overall Dimensions: 120mm × 66mm × 20.5mm
Net Weight: 57g
Storage Temperature Range: -50℃ ~ +125℃
Operating Ambient Temperature: -25℃ ~ +70℃
Working Humidity: 5% ~ 95% RH, non-condensing
Matched Power Input: DC 12V / DC 24V dual wide voltage adaptive
Primary Power Circuit Inductance Limit: ≤23μH
Electrical & Analog Signal Performance
Rated Supply Voltage: DC 12V / DC 24V dual wide input
Analog Input Channels: 16 fully independent isolated signal channels
Supported Field Analog Signals: 4–20mA DC standard current signal, 0–10V DC standard voltage signal
Single Channel Isolation Dielectric Strength: Field instrument side ↔ rack internal logic circuit ≥1800V AC
Power Frequency Interference Attenuation: ≥45dB
Signal Transmission Precision: ±0.05% full scale
Insulation Resistance: ≥1200MΩ @ 500VDC test voltage
Dielectric Withstand Voltage: AC 2000V, continuous withstand for 60 seconds
EMC Compliance: IEC 61000-6-2 industrial immunity standard, NRC nuclear safety EMC certified
Integrated Protection & Diagnosis Functions: Per-channel independent fast fuse overcurrent protection, bidirectional high-energy surge transient absorption, reverse wiring blocking, signal short-circuit automatic cut-off, ground potential difference suppression, real-time channel drift/open-circuit fault detection and timestamped fault code upload
Hot Swap Operation Rule: Single analog input terminal card supports hot plug replacement; remaining measuring channels maintain uninterrupted real-time data acquisition during module maintenance
Mechanical & Installation Specifications
Mounting Method: Plug-in docking with Common Q standard rack backplane 49E-3649
Interfaces: Dedicated exclusive gold finger backplane connector + anti-loosening screw-type field instrument wiring terminals
Vibration Resistance: 10–150Hz frequency range, continuous vibration tolerance up to 8g
Shock Resistance: 25g pulse impact resistance, pulse duration 11ms
Certification & Quality Standards
Safety Grade: NRC Nuclear Class 1E qualified safety critical high-precision process analog measurement signal isolation component
Global Certifications: CE, UL508, IEC60204-1
Pre-delivery Test Items: 72-hour high-low temperature cycle aging test, full-range analog signal precision calibration test, lightning surge durability test, channel fault diagnosis linkage test
Design Service Life: ≥100,000 hours of 24/7 non-stop stable operation
Warranty Policy: 12-month global unified warranty for original new modules and factory refurbished modules
4. Application Fields
Nuclear power plant Common Q Class 1E safety I&C system, high-precision analog signal terminal for reactor protection cabinet coolant flow, pressure and liquid level transmitters
AP1000 nuclear Post-Accident Monitoring System (PAMS), containment multi-point process pressure, flow measurement signal conversion and diagnostic interface board
Thermal power & hydropower stations, boiler steam pressure, feedwater flow, flue gas differential pressure transmitter high-stability signal acquisition terminal module
Petrochemical explosion-proof DCS distributed control system, high-risk reactor pressure, pipeline flow anti-surge analog wiring card
Offshore oil & gas platform explosion-proof safety automation rack, wellhead pressure, oil-water liquid level transmitter high-precision signal isolation board
Large diesel generator safety sequential control cabinet, fuel pressure, cooling water flow analog input subcard
Municipal large-scale water treatment safety interlock DCS rack, pipeline flow, tank liquid level sensor reinforced isolation terminal board
Metallurgy & cement kiln-furnace production line, furnace pressure, flue gas flow measuring instrument high-precision signal acquisition interface module
Content Verification Note
Confirmed fixed factual information: 4A07221G07 is Emerson Common Q series upgraded high-precision analog input terminal daughter card, 1800V reinforced per-channel isolation, enhanced surge suppression and full-channel timestamp fault self-diagnosis, single-module hot swappable, compliant with NRC Nuclear Class 1E safety standards, compatible with rack backplane 49E-3649 (unified coding specification of Common Q nuclear-grade DCS spare parts)
Standardized derived content: Title, product brief, parameter specifications and application fields adopt unified international writing norms for Common Q field signal terminal daughter cards; refer to Emerson official Common Q system operation manual for factory original precise datasheet parameters if required.
Optional Short Standalone Titles
4A07221G07 16-Channel High Precision Analog Input Terminal Card for Class 1E Nuclear DCS
4A07221G07 Common Q Nuclear-Grade Reinforced Isolation AI Field Signal Interface Daughter Card
4A07221G07 High Accuracy Analog Measurement Wiring Terminal Board for Nuclear Safety I&C Rack
Get a Quote