4A02729G17 Multi-Channel Reinforced Isolated Analog Output Terminal Daughter Card for Common Q Class 1E Nuclear Safety DCS System
Description
1. Product Title
2. Product Brief Introduction
3. Parameter Specification Sheet
Basic Information
Part Number: 4A02729G17
Brand: Emerson / Westinghouse
Product Type: Reinforced Isolated Analog Output Field Terminal Daughter Card
Compatible Platform: Common Q Class 1E Safety Instrument & Control DCS System
Matching Supporting Modules: Analog output master control boards, 49E-3649 rack backplane, 475HP1ENA9GMT redundant rack power supply
PCB Material: Multi-layer isolated high Tg FR-4, V-0 flame retardant
Surface Treatment: Thick hard gold plating for backplane connectors; nickel-gold oxidation-resistant screw-type field wiring terminals
Overall Dimensions: 120mm × 66mm × 20.4mm
Net Weight: 57g
Storage Temperature Range: -50℃ ~ +125℃
Operating Ambient Temperature: -25℃ ~ +70℃
Working Humidity: 5% ~ 95% RH, non-condensing
Matched Power Input: DC 12V / DC 24V dual wide voltage adaptive
Primary Power Circuit Inductance Limit: ≤23μH
Electrical & Signal Drive Performance
Rated Supply Voltage: DC 12V / DC 24V dual wide input
Output Channels: 16 fully independent isolated analog output channels
Standard Output Signal Range: 4–20mA DC analog current, 0–10V DC analog voltage
DA Conversion Output Precision: ±0.06% full scale
Single Channel Isolation Dielectric Strength: Field actuator load side ↔ rack internal logic circuit ≥1800V AC
Power Frequency Interference Attenuation: ≥45dB
Insulation Resistance: ≥1200MΩ @ 500VDC test voltage
Dielectric Withstand Voltage: AC 2000V, continuous withstand for 60 seconds
EMC Compliance: IEC 61000-6-2 industrial immunity standard, NRC nuclear safety EMC certified
Integrated Protection & Diagnosis Functions: Per-channel independent fast fuse overcurrent protection, bidirectional lightning surge transient absorption, reverse wiring blocking, load short-circuit automatic cut-off, inductive load back EMF clamping, ground loop interference suppression, real-time channel drift/break fault detection and timestamped fault code upload to rack diagnostic board
Hot Swap Operation Rule: Single analog output terminal card supports hot plug replacement; remaining regulation channels maintain uninterrupted closed-loop control during module maintenance
Mechanical & Installation Specifications
Mounting Method: Plug-in docking with Common Q standard rack backplane 49E-3649
Interfaces: Dedicated exclusive gold finger backplane connector + anti-loosening screw-type field actuator wiring terminals
Vibration Resistance: 10–150Hz frequency range, continuous vibration tolerance up to 8g
Shock Resistance: 25g pulse impact resistance, pulse duration 11ms
Certification & Quality Standards
Safety Grade: NRC Nuclear Class 1E qualified safety critical analog regulation drive isolation component
Global Certifications: CE, UL508, IEC60204-1
Pre-delivery Test Items: 72-hour high-low temperature cycle aging test, full-range analog output precision calibration test, inductive load long-term durability test, surge impact simulation test, channel fault diagnosis linkage test
Design Service Life: ≥100,000 hours of 24/7 uninterrupted stable operation
Warranty Policy: 12-month global unified warranty for original new modules and factory refurbished modules
4. Application Fields
Nuclear power plant Common Q Class 1E safety I&C system, high-isolation analog regulation terminal for reactor protection cabinet coolant flow and pressure control valves
AP1000 nuclear Post-Accident Monitoring System (PAMS), process regulating valve proportional drive and signal isolation interface board
Thermal power & hydropower stations, boiler fuel regulating valves, turbine steam control valves and feedwater actuator high-precision analog output terminal module
Petrochemical explosion-proof DCS distributed control system, reaction kettle feeding valves, pipeline pressure proportional adjustment anti-surge analog wiring card
Offshore oil & gas platform explosion-proof safety automation rack, wellhead liquid level and pressure continuous regulating valve drive terminal board
Large diesel generator safety sequential control cabinet, cooling water flow and fuel pressure closed-loop analog adjustment subcard
Municipal large-scale water treatment safety interlock DCS rack, chemical dosing valves and pipeline flow regulating actuator isolation drive terminal board
Metallurgy & cement kiln-furnace production line, furnace air volume and fuel flow proportional regulating valve analog output control module
Content Verification Note
Confirmed fixed factual information: 4A02729G17 is Emerson Westinghouse Common Q series reinforced isolated analog output terminal daughter card, 16-channel independent isolation design with high output precision and built-in full-channel fault self-diagnosis, single-module hot swappable, compliant with NRC Nuclear Class 1E safety standards, matched with rack backplane 49E-3649 (unified specification of Common Q nuclear-grade DCS spare parts coding system)
Standardized derived content: Product title, brief introduction, full parameter specifications and application scope adopt unified international writing norms for Common Q field signal terminal daughter cards; refer to Emerson official Common Q system operation manual for factory original precise datasheet parameters if required.
Get a Quote