405A975G01
June 08, 2026

405A975G01

405A975G01 is a Power Supply Module (also referenced as Processor Module in some listings) for Westinghouse (Emerson) Ovation™ and WDPF DCS, designed to deliver regulated, isolated power to rack-mounted controller/I/O cards. It’s a critical backplane power source, offering high efficiency, tight voltage regulation, and built-in diagnostics for industrial process control.

Description

2. Basic Information

  • Model Number: 405A975G01

  • Brand: Westinghouse / Emerson

  • Type: DCS Power Supply Module (Backplane & System Power)

  • Applicable Systems: Ovation™ DCS, legacy WDPF DCS

  • Origin: United States

  • Weight: Approx. 1.6 kg

  • Form Factor: Standard Ovation/WDPF slide-in card

  • Warranty: 12 months (new/refurbished)

  • Certifications: Emerson factory tested, CE, EMC, IEC 61010 compliant

3. Key Functions

  1. Backplane Power Distribution: Supplies stable DC power to all rack modules (controllers, I/O, communication cards).

  2. Isolation & Regulation: Provides galvanic isolation and tight voltage regulation to protect sensitive DCS electronics from noise/spikes.

  3. Redundancy Support: Works in 1+1 redundant configs with auto-failover for uninterrupted power.

  4. Overload/Short-Circuit Protection: Built-in current limiting and shutdown to prevent module/backplane damage.

  5. Health Monitoring: Onboard LEDs and fault logging for real-time status and troubleshooting.

  6. Wide Input Compatibility: Accepts industrial AC/DC inputs for flexible cabinet integration.

4. Technical Specifications

4.1 Electrical

  • Input Voltage: 85–264 VAC (47–63 Hz) / 120–370 VDC

  • Output Voltage: 24 VDC (regulated, ±1%)

  • Output Power: 150 W (continuous)

  • Efficiency: ≥85% (full load)

  • Isolation: 1500 VAC (input ↔ output)

  • Protection: Overvoltage, overcurrent, short-circuit, overtemperature

4.2 Environmental

  • Operating Temp: 0 °C to +55 °C

  • Storage Temp: -25 °C to +70 °C

  • Relative Humidity: 5%–95% (non-condensing)

  • Vibration: IEC 60068-2-6 compliant (industrial grade)

4.3 Mechanical

  • Dimensions: Standard Ovation/WDPF module size

  • Mounting: Slide-in, front-locking latch

  • Cooling: Forced air (internal fan)

  • Coating: Conformal coated for dust/moisture resistance

5. Compatibility & Replacement

  • Direct Replacements: 405A975G02 (updated firmware)

  • Compatible With: All Ovation/WDPF racks; pairs with 405A973H01 (processor) and 405A924Gxx (communication) modules.

6. Applications

  • Power Generation: Thermal, combined-cycle, nuclear plants (Ovation/WDPF)

  • Petrochemical: Refineries, gas processing, chemical plants

  • Heavy Industry: Pulp & paper, mining, cement, metallurgy

  • Water Treatment: Large municipal/industrial water/wastewater facilities

7. LED Indicators

  • AC IN (Green): On = AC input OK; Off = no input

  • DC OUT (Green): On = 24 VDC output stable; Flashing = overload

  • FAULT (Red): On = overtemperature/short circuit; Flashing = fan failure

  • REDUND (Blue): On = redundant partner active

8. Installation & Safety

  1. Power Off: Disconnect cabinet AC before insertion/removal.

  2. ESD Protection: Use anti-static wristband/mat.

  3. Insertion: Align with slot guides; push until latch clicks.

  4. Wiring: Connect AC input per local codes; torque terminals to specs.

  5. Grounding: Connect module ground to cabinet earth (<1 Ω).

  6. Power-Up: Restore AC; verify LEDs; check output voltage via meter.

9. Maintenance & Troubleshooting

  • Routine Checks: Inspect LEDs, fan airflow, and connections quarterly; clean fan filters semi-annually.

  • Common Issues:

    • No DC OUT: Check AC input, fuse, and wiring.

    • FAULT Light On: Clear air vents; check for short circuits on backplane.

  • Firmware: Update via Emerson tools; match redundant module firmware.

10. Ordering Information

  • Part Number: 405A975G01

  • Category: DCS Spare Parts → Ovation/WDPF → Power Supply Modules

  • Availability: New original and tested refurbished units in stock

  • Lead Time: 1–3 days (in stock); 2–4 weeks (special order)

  • Order Note: Specify rack serial number and redundancy config for compatibility.


Get a Quote