3A99116G01
Description
1. Product Basic Info
2. Core Function Definition
Primary power management & closed-loop voltage regulation to generate +5VDC, ±12VDC regulated power for Q-Line VME backplane;
Overvoltage/undervoltage/overcurrent/short-circuit protection logic for full crate I/O modules;
AC-DC auxiliary sampling & fault diagnostic circuit, feeds power failure alarm signal to DPU main controller;
Temperature monitoring for internal power transformer and power semiconductor components, triggers overheat protection automatically.
3. Electrical Specifications
Input Side (From Main Power Supply 5D32191G01)
AC Input Range: 85~264VAC, 47~63Hz universal industrial input
Regulated DC Output (To VME Backplane)
| Rated Output | Nominal Voltage | Max Continuous Output Current |
|---|---|---|
| Channel 1 | +5VDC | 18A |
| Channel 2 | +12VDC | 6A |
| Channel 3 | -12VDC | 6A |
Output precision: ±1% full load regulation; Ripple ≤20mVpp
Protection Specifications
OVP: +5V>5.7V / ±12V>14.5V auto shut down
OCP: Current exceed 120% rated value → hiccup mode protection
OTP: Internal temp>85℃ cut off output power
4. Environmental Parameters
Operating Temp: 0℃ ~ +55℃ (inside sealed control cabinet)
Storage Temp: -40℃ ~ +85℃
Ambient Humidity: 5%~95%RH non-condensing, no corrosive gas, no conductive dust
EMC: Built-in multi-stage EMI filter, compliant with CE industrial control standard for power plant EH cabinet environment
5. Installation & Replacement Instruction
The board is plug-in fixed inside 4MDPS9/5D32191G01 power chassis; cut off cabinet AC input before disassembling;
Direct drop-in replacement for same G01 revision variant; no parameter modification required after replacement;
After replacement: Power on no-load first, measure +5V/±12V output voltage via test terminals before loading full rack I/O cards.
6. Application Scope
7. Commercial & Maintenance Info
OEM original production permanently discontinued; available stock: fully tested refurbished PCB & inspected used original spare parts;
Standard repair cycle: 2~4 weeks, rush emergency maintenance service available; global shipping via DHL/UPS/FedEx.
8. Common Troubleshooting
Full rack module no power: Check AC input of main power chassis, inspect fuse on 3A99116G01 PCB;
Output voltage drift: Replace aging sampling resistors or voltage reference chip on MDPS board;
Random power shutdown: Abnormal internal temperature → clean chassis dust or check cooling ventilation of power cabinet.