3869-097-300-131VDC-R0
June 05, 2026

3869-097-300-131VDC-R0

This unit belongs to 3869 series three-phase phase-angle SCR rectifier DC power controller, adopting six SCR components to form full-bridge three-phase rectifier circuit, converting 3-phase alternating current to adjustable direct current output. It linearly regulates output DC voltage/current according to external analog control signal (0~10VDC standard for R0 option), mainly used for industrial heating furnace, electroplating rectifier, DC motor drive and thermal processing equipment power regulation.

Description

1. Product Overview

Manufacturer: Control Concepts (USA)
Model: 3869-097-300-131VDC-R0
This unit belongs to 3869 series three-phase phase-angle SCR rectifier DC power controller, adopting six SCR components to form full-bridge three-phase rectifier circuit, converting 3-phase alternating current to adjustable direct current output. It linearly regulates output DC voltage/current according to external analog control signal (0~10VDC standard for R0 option), mainly used for industrial heating furnace, electroplating rectifier, DC motor drive and thermal processing equipment power regulation.

Model Code Definition

  • 3869 = product series (3-phase DC SCR controller series)

  • 097 = input rated AC voltage: 97VAC

  • 300 = continuous rated DC output current: 300A

  • 131VDC = internal auxiliary control power supply: DC131V

  • R0 = control signal configuration: 0–10VDC analog input command (I0/10V)

2. Key Electrical Specifications

表格
ItemParameter
Input Power3 Phase, 97VAC, 50/60Hz
Rated DC OutputMax Continuous 300A DC, adjustable voltage via phase-angle control
Control Command Signal0~10VDC analog input (R0 standard type), linear 0-100% output corresponding to input 0-10V
Internal Auxiliary SupplyControl circuit powered by 131VDC fixed input
Control ModePhase-angle firing regulation, voltage closed-loop feedback control
Cooling MethodDual built-in axial cooling fans + large aluminum finned heat sink for forced air cooling
Protective Functions① Shorted SCR fault detection & alarm; ② Over-current shutdown trip protection; ③ Internal overheat protection; ④ Input surge anti-interference circuit
Operating Ambient Temp0℃ ~ +60℃ (working); -40℃ ~ +85℃ (storage environment)
Housing StructureVertical base mounting, heavy-duty industrial all-metal red casing, copper busbar terminal wiring design

3. Core Product Features

  1. Precise linear power adjustment: output DC value changes proportionally following analog command voltage, high regulation accuracy for constant power load control.

  2. Built-in comprehensive fault diagnosis circuit, external alarm terminal for SCR short-circuit and over-current failure signal output.

  3. Heavy current copper bus connection terminals, optimized high-current circuit layout to reduce heat loss under full-load operation.

  4. Independent control power loop powered by 131VDC, stable operation unaffected by fluctuation of main 3-phase 97VAC input grid.

  5. Obsolete original series; new replacement model: Control Concepts FUSION series three-phase DC SCR power controller.

4. Typical Application Range

  • Industrial resistance heating furnaces, metallurgy thermal processing production lines

  • Electroplating & electrolysis DC rectifier power source equipment

  • Heavy-duty DC motor speed regulation & excitation power supply

  • Chemical coating, plastic extrusion heating loop power control

5. Installation & Operation Instructions

  1. Fix equipment vertically on solid metal base with mounting bolts, reserve ≥150mm ventilation space around heat sink for air circulation.

  2. Confirm main input: 3PH 97VAC and auxiliary control input: DC131VDC match nameplate parameter before power-on test.

  3. Connect external 0~10VDC control command signal to corresponding control terminal; verify wiring polarity correctly.

  4. After energization, check cooling fans run smoothly without abnormal noise; stop operation immediately once overheat or fault alarm occurs.

  5. Periodically clean dust accumulated on heat sink and internal PCB circuit every 3–6 months to avoid poor heat dissipation damage.

6. Storage Requirement

Store spare controller in dry, dust-free warehouse without corrosive gas and strong electromagnetic interference; regular short-period energization inspection every half-year is recommended for long-term stocked spare parts.


Get a Quote