3051C*6672678
Description
1. Product Introduction
2. Core Technical Data
Reference accuracy: up to ±0.04% FS, total performance error ≤0.15% full scale
Turndown ratio: max 150:1 adjustable measuring span
Supply: 10.5~42.4VDC loop power for 4–20mA/HART version
Wetted material default: 316L stainless steel; optional Hastelloy C, Monel, Tantalum for corrosive medium
Communication options: HART7, FOUNDATION Fieldbus, Profibus PA, WirelessHART
3. Built-in Functions
Optional backlit local LCD display for field reading and zero/span trimming
Intelligent diagnosis: plugged impulse line detection, loop fault alarm, process abnormal early warning
Available SIL2/SIL3 safety certification (IEC61508), ATEX/FM explosion-proof for hazardous area installation
On-device push-button calibration without extra tooling
4. Working Environment
Ambient temp: -40℃ ~ +85℃; storage temp: -40℃ ~ +85℃
Humidity: 5%~95%RH non-condensing
Medium temp varies by filling fluid configuration, standard range -40℃~120℃
5. Main Application
Orifice/annubar differential flow measurement
Closed tank liquid level via DP measurement
Boiler, reactor, pipeline real-time pressure monitoring in chemical & power plant
Get a Quote