DKR03.1-W200N-BE43-02 | Bosch Rexroth Indramat DIAX03 SERCOS Modular Spindle Drive
Description
Model Code Definition
DKR:Independent cabinet heavy-duty spindle driver of DIAX series
03:Third-generation DIAX03 hardware platform
.1:Main power board hardware revision V1
W:Built-in axial fan forced convection cooling
200:Continuous rated output current 200Arms
N:Zero internal brake bleeder circuit, external brake resistor required
BE:SERCOS fiber digital bus control PCB (pure fiber bus command, no default ±10V analog speed input)
43:Top-tier expandable SERCOS control board with native RS232+RS485 dual serial interface + multi U-type expansion slots for optional function modules
02:Control mainboard hardware revision V02
Technical Specifications
Input Power:3Φ AC400~480V ±10% 50/60Hz; independent single-phase AC230V auxiliary control supply (200VA)
Nominal DC Bus:700VDC
Output Rating:Continuous 200A RMS; 250% overload sustain 300ms, 300% instantaneous peak overload; max output frequency 1600Hz, matching approx 62kW Indramat 2AD/ADF/1MB spindle motors; default PWM carrier 4kHz, optional 8kHz with partial current derating
Brake Configuration:No internal bleeder, external high-power braking resistor required for all deceleration & regenerative working conditions
Cooling:Integrated cabinet blower, total internal power loss ~1370W
Protection Class:IP20 (EN60529), vertical cabinet exclusive installation
Ambient Operation:0~+45℃ full-load continuous operation, automatic output derating above 45℃; storage -30~+85℃; installation altitude ≤1000m; relative humidity<90% non-condensing
Dimension & Net Weight:H822×W350×D353mm, approx 49.5kg
Compatible Motors:Indramat 1MB frameless spindle, 2AD/ADF AC spindle, LAF/LSF synchronous linear servo motors
Interface & Communication Configuration
Main Power Terminals:Heavy-duty screw terminals L1/L2/L3 three-phase mains input, U/V/W high-current motor output terminals
Bus Interface:Dual IN/OUT SERCOS fiber optic ports for multi-axis daisy-chain ring bus layout, no onboard analog ±10V command terminal
Dual Serial Port (BE43 exclusive):Front panel integrated RS232 (9600/19200 baud, max 15m wiring for IndraWorks debugging) + RS485 (same baud rate, max 500m multi-drop bus for remote multi-drive networking, up to 30 nodes)
Feedback Port:1×15Pin D-SUB connector, compatible with resolver, TTL incremental encoder, sine/cosine high-resolution encoder signals
Onboard IO:Base fixed 8DI/4DO digital terminal; reserved U1~U5 five expansion slots for optional IO, positioning or auxiliary fieldbus plug-in modules
Auxiliary Terminal Strip:Drive enable, hardware E-stop, motor PTC thermal protection, fault dry contact relay, drive ready status terminals
DSM Slot:Front vacant memory card slot, no factory pre-installed firmware DSM card for non-FW variant
Core Functions
Three-loop (current-speed-position) full digital closed-loop control via SERCOS real-time fiber bus; native dual serial bus is core advantage of BE43 versus BE11/BE12/BE23/BE31: RS232 for local single-drive parameter tuning & fault diagnosis, RS485 for multi-drive centralized remote monitoring; base spindle functions: constant-speed regulation, high-precision C-axis rotary positioning, rigid tapping; expand electronic gearing & multi-segment electronic cam by installing optional U-slot plug-in modules; comprehensive protection: overcurrent, DC bus over/undervoltage, IGBT overheat, fan failure, feedback cable breakage, front digital LED fault code indication; non-FW blank slot unit cannot power up directly, must equip matched programmed DSM and complete firmware flashing via IndraWorks software。
Application Fields
High-end multi-axis SERCOS bus CNC machining center spindle, long-distance distributed multi-spindle synchronous printing & textile production line, customized heavy-duty special CNC equipment requiring remote RS485 centralized control, old analog CNC digital retrofit with expandable peripheral IO demand.
Operation & Maintenance Instructions
Only connect three-phase AC400~480V industrial mains; single-phase power input triggers DC bus undervoltage lockout with zero output.
Reserve ≥90mm upper and lower cabinet ventilation clearance to avoid insufficient blower cooling causing overheat shutdown and output derating.
N-type non-internal bleeder design: external matched braking resistor must be configured regardless of continuous or intermittent deceleration.
BE43 dual-serial mainboard cannot be directly interchanged with BE11/BE12/BE23/BE31 control PCB; mismatched hardware leads to serial communication failure or abnormal axis operation.
Non-FW version needs original DSM parameter backup during maintenance; replacement DSM requires full firmware rewrite via IndraWorks to match original program version.