DKR03.1-W200N-BE23-01-FW | Bosch Rexroth Indramat DIAX03 Top-Grade SERCOS Spindle Drive
Description
Model Code Definition
DKR:Independent cabinet-type high-power spindle driver of DIAX series
03:3rd-gen DIAX03 hardware platform
.1:Main power board hardware revision V1
W:Integrated built-in fan forced air cooling
200:Continuous rated output current 200Arms
N:No internal brake bleeder circuit, external brake resistor mandatory
BE:SERCOS fiber digital bus control PCB (pure fiber bus command, no default ±10V analog speed input)
23:Top-tier full-feature SERCOS control mainboard, complete advanced motion control functions
01:Control board hardware revision V01
FW:Factory preloaded programmed DSM card with standard ESM03 firmware
Technical Specifications
Input Power:3Φ AC400~480V ±10% 50/60Hz; independent single-phase AC230V auxiliary control supply (200VA)
Nominal DC Bus:700VDC
Output Rating:Continuous 200A RMS; 250% overload sustainable for 300ms, 300% instantaneous peak overload; max output frequency 1600Hz, matching approx 62kW Indramat 2AD/ADF/1MB spindle motors; default PWM carrier 4kHz, optional 8kHz with partial current derating
Brake Configuration:Zero internal bleeder, external high-power braking resistor required for all deceleration & regenerative working conditions
Cooling:Integrated cabinet blower, total internal power loss ~1370W
Protection Class:IP20 (EN60529), vertical cabinet-only installation
Ambient Operation:0~+45℃ full-load continuous run, automatic output derating above 45℃; storage -30~+85℃; installation altitude ≤1000m; relative humidity<90% non-condensing
Dimension & Net Weight:H822×W350×D353mm, approx 50.2kg
Compatible Motors:Indramat 1MB frameless spindle, 2AD/ADF AC spindle, LAF/LSF synchronous linear servo motors
Interface & Communication Configuration
Main Power Terminals:Heavy-duty screw terminals L1/L2/L3 three-phase mains input, U/V/W high-current motor output terminals
Bus Interface:Dual IN/OUT SERCOS fiber optic ports for multi-axis daisy-chain bus layout, no analog ±10V command terminal
Feedback Port:1×15Pin D-SUB connector, compatible with resolver, TTL incremental encoder, sine/cosine high-resolution encoder signals
Onboard IO:16DI/10DO digital terminal bank + dual U2/U3 optional expansion slots for auxiliary function card (higher IO quantity vs BE11/BE12 versions)
Debug Port:Front-panel RS232 serial port (9600/19200 baud), for IndraWorks parameter setting, fault diagnosis and parameter backup
Auxiliary Terminal Strip:Drive enable, hardware E-stop, motor PTC thermal protection, fault dry contact relay, drive ready status terminals
DSM Slot:Front slot pre-installed factory programmed DSM-FW card, firmware pre-written at manufacture
Core Functions
Three-loop (current-speed-position) full digital closed-loop control via SERCOS real-time fiber bus; full BE23 feature set: basic spindle constant-speed regulation, high-precision C-axis rotary positioning, rigid tapping, full electronic gearing synchronization + multi-segment electronic cam curve operation (advanced functions unavailable on BE11/BE12); comprehensive fault protection: overcurrent, DC bus over/undervoltage, IGBT overheat, fan malfunction, feedback cable breakage, front digital LED fault code indication; FW pre-firmware model powers on ready directly without offline firmware download or DSM card programming.
Application Fields
High-precision 5-axis CNC machining center SERCOS bus spindle, multi-axis synchronous printing & packaging production line main spindle, complex cam machining CNC lathe with full C-axis function, digital retrofitting for premium old analog CNC equipment.
Operation & Maintenance Instructions
Only feed three-phase AC400~480V industrial mains; single-phase input triggers DC bus undervoltage lockout with no output.
Reserve ≥90mm upper and lower cabinet ventilation gap to avoid overheat protection trip and output derating from insufficient blower cooling.
N-type non-internal bleeder design: external matching braking resistor must be equipped for any intermittent or continuous deceleration scenarios.
BE23 premium control board cannot directly replace BE11/BE12 lower-spec control PCB; mismatched hardware leads to axis jitter or runaway.
FW version must retain original DSM card intact during maintenance; replacement DSM requires full firmware rewrite via IndraWorks software to match original program version.