DKR03.1-W200N-BE23-01 | Bosch Rexroth Indramat DIAX03 High-End SERCOS Spindle Drive
Description
Model Code Definition
DKR:Independent high-power cabinet spindle driver of DIAX series
03:3rd generation DIAX03 hardware platform
.1:Main power board hardware revision V1
W:Integrated axial fan forced convection cooling
200:Continuous rated output current 200Arms
N:No built-in internal brake bleeder chopper, external braking resistor required
BE:SERCOS fiber digital bus control PCB (pure digital bus command, no standard ±10V analog interface)
23:High-end full-function SERCOS control board, full advanced motion algorithm support
01:Control board hardware revision V01
Technical Specifications
Input Power:3Φ AC400~480V ±10% 50/60Hz; independent single-phase AC230V auxiliary control power(200VA)
Nominal DC Bus:700VDC
Output Rating:Continuous 200A RMS; 250% overload sustain 300ms, 300% instantaneous peak overload; max output frequency 1600Hz, matches ~62kW Indramat 2AD/ADF/1MB spindle motor; default PWM 4kHz, optional 8kHz with partial output derate
Brake Setting:Zero internal bleeder circuit, external high-power braking resistor required for all deceleration/regenerative operation
Cooling:Integrated cabinet blower, total power loss ~1370W
Protection Class:IP20 per EN60529, vertical cabinet mounting only
Ambient Working:0~+45℃ full-load running, automatic current derate above 45℃; storage -30~+85℃; altitude ≤1000m; RH<90% non-condensing
Dimension & Weight:H822×W350×D353mm, net approx 50.2kg
Compatible Motors:Indramat 1MB frameless spindle, 2AD/ADF AC spindle, LAF/LSF linear synchronous servo motors
Interface & Communication Configuration
Main Power Terminals:Heavy-duty L1/L2/L3 mains input, U/V/W high-current motor output terminals
Bus Interface:Dual IN/OUT SERCOS fiber optic ports for multi-axis daisy-chain bus connection, no analog ±10V speed command terminal
Feedback Port:1×15Pin D-SUB connector, compatible with resolver, TTL incremental encoder, sine/cosine high-resolution encoder
Onboard IO:Expanded 16DI/10DO digital terminal bank + dual reserved U2/U3 expansion slots for optional auxiliary function card(superior to BE11(8DI/5DO)/BE12(12DI/7DO))
Debug Port:Front RS232 serial port (9600/19200 baud) for IndraWorks parameter tuning, fault diagnosis & parameter backup
Auxiliary Terminal:Drive enable, hardware E-stop, motor PTC thermal detection, fault relay dry contact, drive ready signal terminals
DSM Slot:Front vacant memory card slot on non-FW model, no factory pre-installed firmware card
Core Functions
Full current-speed-position triple closed-loop digital control via SERCOS fiber bus; BE23 full feature set: basic spindle constant speed, C-axis precision rotary positioning, rigid tapping, full electronic gearing synchronization + multi-segment electronic cam curve operation (core advanced function unavailable on BE11/BE12); complete protective functions: overcurrent, DC bus over/undervoltage, IGBT overheat, fan fault, feedback cable break, front LED digital fault code display; non-FW blank slot unit cannot startup directly after power-on, must install matched programmed DSM card and download dedicated ESM03 firmware via IndraWorks software。
Application Fields
High-end 5-axis CNC machining center SERCOS bus spindle, multi-axis synchronous printing/packaging production line spindle, high-precision CNC lathe with complex C-axis cam machining, old high-grade analog CNC digital upgrade transformation project。
Operation & Maintenance Instructions
Strictly apply three-phase AC400~480V industrial mains; single-phase power input triggers DC bus undervoltage lockout with zero output.
Reserve ≥90mm upper/lower cabinet ventilation clearance to avoid insufficient blower cooling leading to overheat protection shutdown and output derating.
N-type no internal bleeder design: matched external braking resistor must be configured regardless of continuous or intermittent stop mode.
BE23 premium control board cannot be directly interchanged with BE11/BE12 lower-grade mainboard, function mismatch causes abnormal axis jitter or runaway.
Non-FW version: preserve original DSM parameter backup during maintenance; replacement DSM requires full firmware rewrite via IndraWorks.