DKR02.1-W300N-B | Bosch Rexroth Indramat DIAX02 300A Base Power Unit
Description
Model Code Definition
DKR = DIAX02 heavy current single-axis spindle drive series
02 = 2nd generation DIAX hardware platform
.1 = Hardware Revision V1
W = Internal axial blower forced air cooling
300 = Continuous rated output current 300Arms
N = No built-in internal bleeder brake chopper(无内置制动斩波器)
B = Standard base power chassis without pre-installed control card(裸功率底座,不含主控板)
No suffix = Empty front FW card slot, no preloaded firmware
Technical Specifications
Main Input:3Φ AC400~480V ±10%,50/60Hz;isolated DC24V auxiliary control power
DC Bus nominal voltage:700VDC
Output rating:Continuous 300A RMS;250% overload sustain 300ms,300% instantaneous peak overload;max output frequency1200Hz,max matched spindle power≈93kW;switching freq optional4kHz/8kHz(derate to141A@4kHz,110A@8kHz)
Braking setup:N-type no internal bleeder,all regenerative braking energy requires external high-power braking resistor installation for deceleration & emergency stop
Cooling:Built-in cabinet blower forced convection,overall internal loss≈1810W
Protection grade:IP20(IEC),vertical cabinet exclusive installation
Ambient condition:Full-load 0~+45℃(auto derate over 45℃);storage -30~+85℃;altitude≤1000m;RH<90% non-condensing
Dimension&Weight:H1065×W468×D392mm,net weight≈59.8kg
Interface & Communication Configuration
Power terminals:Heavy-duty L1/L2/L3 mains input,U/V/W high-current motor output terminals
Slot layout:U1~U4 all vacant empty slots for post-install BE/BA control mainboard、feedback board、IO extension modules
Auxiliary terminals:Drive enable,E-stop,motor thermal protection,fault relay dry contact,ready status terminals reserved on terminal strip
Debug port:Front RS232 reserved socket(only valid after control board fitted)
FW slot:Independent empty front slot for optional DSM firmware memory card post-assembly
Core Functions
Pure power conversion base without independent control logic;all speed/position/torque closed-loop functions depend on later plug-in BE/BA series control motherboard;complete hardware protection including overcurrent,DC bus over/undervoltage,power module overtemperature,fan fault,front LED alarm indicator reserved;after full control card + FW card assembled,enables standard three-loop spindle closed-loop control,electronic gearing,C-axis indexing,rigid tapping functions。
Application Fields
Spare replacement power base for heavy-duty vertical/horizontal CNC machining center main spindle drive,large gravure printing main drive,heavy metallurgy winding spindle,legacy imported machine tool drive retrofit project;users configure matched BE/BA control card per original machine program requirement。
Operation & Maintenance Instructions
Only access standard three-phase AC400~480V industrial mains,single-phase power leads to persistent DC bus undervoltage interlock.
Keep ≥100mm top&bottom ventilation gap inside cabinet to guarantee blower airflow,avoid overheating derating or shutdown.
N-type no internal brake chopper:must configure external matched braking resistor for frequent deceleration or emergency braking to prevent DC bus overvoltage trip.
Unit cannot run standalone;must equip corresponding BE/BA mainboard + matching FW memory card to complete commissioning via IndraWorks software.
For field replacement,confirm original control board model(BEXX/BAXX)first before purchasing matching plug-in control module.
Get a Quote