DKC14.3-040-7-FW | Bosch Rexroth Indramat ECODRIVE03 Servo Drive
Description
Model Code Definition
DKC:ECODRIVE03 full digital servo drive series code
14.3:14 series, Revision3 hardware, expansion slot for optional fieldbus daughterboard, passive natural cooling structure
040:rated continuous output current = 40Arms
7:high voltage grade, 3-phase AC380~480V input, nominal DC bus 700VDC
FW:general basic firmware, standard three-loop control, no electronic cam/electronic gearing sync function (vs FM firmware)
Technical Specifications
Main Power:3Φ AC380~480V ±10%,50/60Hz; separate external DC24V±10% control power supply
DC Bus:700VDC nominal, built-in pre-charge circuit & integrated dynamic brake module
Output Parameter:40A continuous current, 250% overload lasting 300ms, optional 4kHz/8kHz PWM carrier, max output frequency 1000Hz
Mechanical Size:W105mm×H360mm×D261mm, net weight≈7.2kg, IP20 cabinet DIN mounting, no built-in cooling fan
Ambient Condition:0~45℃ full-load operation; derated run up to 55℃; storage -35~+85℃; altitude≤1000m; relative humidity<90% non-condensing; ≥50mm upper/lower cabinet ventilation gap required for heat dissipation
Interface & Communication Configuration
Power Terminals:L1/L2/L3 mains input, U/V/W motor output, dedicated terminal for external braking resistor
Feedback Port:15pin D-SUB dual feedback interface, support TTL incremental ABZ encoder + resolver, isolated 5V encoder power onboard
Digital I/O:8DI+8DO for drive enable, limit switch, homing, motor brake logic; expandable via option card
Command Interface:±10V analog speed/torque signal, pulse+direction position command
Debug & Fieldbus:Front X1 RS232 for DriveTop parameter setup; Profibus-DP / CANopen / SERCOS via plug-in option board
Core Functions
Full closed-loop position/speed/torque triple regulation; three running modes: analog speed control, pulse positioning, multi-step fixed positioning triggered by digital input. Integrated STO safe torque off, full protection against overcurrent, bus over/undervoltage, IGBT overheat, encoder fault; front LED fault code indication. Lacks master-slave sync and electronic cam compared with FM version drive.
Application Fields
Medium-load CNC feed axes, mid-sized rotary printing machines, medium winding/slitting equipment, automatic packaging & assembling lines.
Operation & Maintenance Instructions
Type7 only connects 3-phase 380~480V AC; single-phase 220V input leads to persistent DC bus undervoltage alarm and insufficient output torque.
Passive cooling design must retain specified cabinet clearance; closed confined installation causes frequent overheat shutdown.
High cyclic forward/reverse working condition needs external high-power braking resistor to avoid internal brake burnout.
Parameter upload/download requires matched DriveTop software version; parameters cannot be copied cross FW/FM firmware directly.