DKC03.3-040-7-FW | Rexroth Indramat ECODRIVE03 Third Generation PROFIBUS 40A High-Pressure Base Station Servo Drive
Description
Model Explanation
DKC: Indramat ECODRIVE03 Full Digital Servo Drive Series
03.3: 03 = Native PROFIBUS-DP hardware platform, .3 = Third-generation hardware optimization version
040: Continuous rated output current 40Arms
7: High-voltage power supply specification, three-phase AC380~480V input, DC bus rated 700VDC
FW: Blank Base power base, without control motherboard, no factory-固化 driver firmware
Technical Parameters
Main circuit power supply: Three-phase AC380~480V ±10%, 50/60Hz; Independent DC24V/2A control power supply
DC bus: Rated 700VDC, hardware overvoltage protection threshold 850VDC
Output capacity: Rated continuous 40Arms, peak 96A (240% rated short-time overload 400ms), output frequency 0~1000Hz
Built-in braking circuit: Built-in energy dissipation peak 8.5kW, high-frequency reciprocating load requires external large-power braking resistor
Overall size: W65×H360×D261mm, net weight 6.5kg
Protection level: IP20 cabinet-mounted vertical installation, 0~45℃ full-load operation, >45℃ reduced power usage, installation altitude ≤1000m
Compatible motors: MKD06/MKD07, MAC07/MAC09, MHD07 series 7.5kW~15kW synchronous servo motors
Interface and Communication Configuration
Power terminals: L1/L2/L3 three-phase incoming line, U/V/W motor power terminals, dedicated terminal for external braking resistor
Encoder interface: Special aviation feedback socket, compatible with rotary transformers, TTL incremental ABZ dual-channel encoder feedback
Board slot: Top-mounted slot on the body, assembly of MGP main control card, card body outputs DI/DO switch quantities, ±10V analog speed control, pulse direction command terminals
Communication Ports
1. RS232 debugging serial port (activated by MGP card): IndraWorks parameter debugging, firmware version burning and upgrading
2. Native integrated PROFIBUS-DP bus interface of the body, no need for additional bus sub-card selection
3. Card slot can select to expand CANopen communication sub-card to achieve dual-bus compatible control Core function
The FW base only has the power circuit, and all the motion control logic is implemented by the MGP main control card.
The MGP card integration: ±10V analog speed regulation + pulse position control + PROFIBUS-DP bus communication in one. It supports electronic gear synchronization, origin search, and automatic control of servo brake timing.
The complete set of standard hardware protection: overcurrent, overvoltage, undervoltage, power module overheating, encoder break, and inter-phase short circuit faults of output stop alarms. Applicable scenarios
Medium-sized CNC machines, rubber and plastic extrusion auxiliary machines, wide-format printing equipment, medium-load winding machines, multi-axis automated assembly lines (PROFIBUS bus control system)
Usage and Maintenance
1.7 models with suffix "high voltage" must not be connected to AC220V single-phase / three-phase power supply. They are only allowed to be powered by industrial three-phase 380V.
2. The FW bare base cannot be powered on and run independently. It must be equipped with MGP main control card + matching corresponding ECODR3 firmware program.
3. The MGP main control card of the full series 016/040/100 power segments of DKC03 is hardware universal. Spare parts can be interchanged across power segments.
4. For high-frequency forward-reverse operation and large inertia conditions, external braking resistors must be forcibly matched to avoid overheating and burning of the built-in braking circuit.
Get a Quote