DKC03.3-016-7-FW | Rexroth Indramat ECODRIVE03 Third Generation PROFIBUS Compact Bottom Mounting Base
Description
Model Explanation
DKC: Indramat ECODRIVE03 servo drive controller
03.3: 03 = PROFIBUS-DP bus architecture, .3 = Third-generation optimized hardware model
016: Continuous rated output current 16Arms
7: High-voltage power supply specification, three-phase AC380~480V input, DC bus 700VDC
FW: Blank Base power-off base, without built-in control board, no factory firmware program
Technical Parameters
Main power supply: Three-phase AC380~480V ±10%, 50/60Hz; independent DC24V control power supply
DC bus: Rated 700VDC, overvoltage protection 850VDC
Output performance: Continuous 16Arms, peak 38.4A (240% rated overload 400ms), output frequency 0~1000Hz
Built-in braking: Built-in energy consumption braking circuit peak 2.8kW, external braking resistor required for frequent start-stop conditions
Dimensions: W55×H182×D170mm, net weight 1.8kg
Protection level: IP20 cabinet-mounted vertical installation, 0~45℃ full load, >45℃ reduced use, altitude ≤1000m
Compatible motors: MKD02/MKD04, MAC03~MAC05 series 1.5kW~5.5kW AC servo motors
Interface and Communication Configuration
Power terminals: L1/L2/L3 three-phase incoming line, U/V/W motor power connection, external braking resistor terminal
Encoder interface: Special aviation feedback socket, compatible with rotary transformers, TTL incremental ABZ encoder
Board slot: Upper slot equipped with MGP main control card, leads DI/DO, ±10V analog, pulse direction instruction
Communication Ports
1. RS232 debugging port (activated by mounting): IndraWorks parameter debugging, firmware burning and upgrading
2. Standard card slot can be selected with DKC03.3-LK-PBK02 sub-card to achieve PROFIBUS-DP bus communication
3. expansion position can be added with CANopen communication sub-card Core function
The FW base only has the power inverter circuit, and all the control logic is implemented by the MGP control card.
The MGP card integration: ±10V analog speed regulation + pulse position + bus communication in one. It supports automatic control of electronic gears, zero-point return to zero, and motor brake timing when the motor is engaged.
Full hardware protection: overcurrent, overvoltage, undervoltage, module overheating, encoder break, output short-circuit fault shutdown alarm. Applicable scenarios
Small packaging machinery, precision assembly fixtures, small printing machines, automated conveying lines, micro CNC equipment (PROFIBUS bus control system)
Usage and Maintenance
1.7 High-voltage models are strictly prohibited from being connected to AC220V power supply. They are only suitable for three-phase 380V industrial power supply.
2. The FW bare base cannot be powered on and operated independently. It must be equipped with the MGP main control card and the matching firmware must be written.
3. The DKC03 full series of 016/040/100 power segments of the MGP card have common hardware and spare parts can be interchanged across power levels.
4. High-frequency reciprocating start-stop loads must be equipped with an external braking resistor to prevent the built-in braking circuit from overheating and being damaged.