DKC03.1-040-7-FW | Rexroth Indramat ECODRIVE03 Profibus Type High Voltage Base Drive
Description
Model Explanation
DKC: Indramat Servo Drive Controller
03.1: Hardware Model, 03 = Profibus-DP Bus Platform, .1 = First Generation Hardware Architecture
040: Continuous Rated Output Current 40Amps
7: High Voltage Specification, Input AC 380~480V, DC Bus 700VDC
FW: Blank Base, No Pre-installed Control Program, No Main Control Board Technical Specifications
Main power supply: Three-phase AC380~480V ± 10%, 50/60Hz; Independent DC24V control power supply
DC bus: Rated 700VDC, Overvoltage protection threshold 850VDC
Output performance: Continuous 40Arms, Peak 96A (240% overload 400ms short time), Output frequency 0~1000Hz
Built-in braking: Built-in discharge circuit peak 10kW, Frequent start-stop loads need external braking resistors
Dimensions: W70×H270×D205mm, Net weight 5.38kg
Environmental specifications: IP20 cabinet installation, 0~45℃ full load operation, Altitude ≤1000m
Compatible motors: MKD09, MKD11, MAC09/11 series 7.5kW~15kW AC servo motors
Interface and communication configuration
Power terminals: L1/L2/L3 three-phase incoming line, U/V/W motor power connection, External braking resistor terminal
Encoder interface: Integrated aviation socket, Compatible with rotary encoder, TTL incremental ABZ dual-channel feedback
Board slot: Top slot for installing MGP main control card, Exports DI/DO, ±10V analog quantity, Pulse command terminals
Communication ports
1. RS232 debugging port (activated by mounting): IndraWorks parameter debugging, firmware flashing
2. The body is standardly equipped with Profibus-DP interface, No additional sub-card selection required
3. Optional expansion of CANopen sub-card (addition of card slot) Core function
The bare base unit only has the power inverter circuit, and the control functions are defined by the MGP control card.
-MGP card: ±10V analog speed regulation + pulse position + Profibus-DP bus integrated control, supporting electronic gear, zero-point return to zero, and motor brake timing control.
Overall hardware protection of the machine: overcurrent, overvoltage, undervoltage, overheating, encoder break, output short circuit, all fault alarm protection. Applicable scenarios
Packaging automation line, printing machinery, general numerical control equipment, automated assembly mechanical hands, small plastic and rubber extrusion equipment (Profibus bus control system)
Usage and Maintenance
1.7 suffix high-voltage models are prohibited from being connected to single-phase / three-phase AC220V power supply. They are only allowed to be powered by industrial three-phase 380V power supply.
2. The FW empty base cannot be powered on and debugged independently. It must be equipped with MGP main control card + matching corresponding firmware version.
3. The same series DKC full-power range (012/040/100/200) MGP control cards have common hardware and interchangeable spare parts.
4. For large inertia frequent forward and reverse operation conditions, a large power braking resistor must be externally connected to prevent the built-in braking circuit from overloading and burning out.