Product Specification: B&R X20AI1744 Analog Input Module
Description

Product Specification: B&R X20AI1744 Analog Input Module
1. General Information
Manufacturer: B&R Industrial Automation
Part Number: X20AI1744
Alternative Designation: X20 AI1744
Product Type: 1-Channel Full-Bridge Strain Gauge Analog Input Module
Product Series: X20 System (Distributed Cabinet I/O)
B&R ID Code: 0x1CDEB& R Industrial Automation
Certifications: CE, UKCA, ATEX (Zone 2, II 3G Ex nA nC IIA T5 Gc), cULus (E115267), KCB& R Industrial Automation
Product Status: Active (Current Production)
2. Core Description
3. Technical Specifications
3.1 Analog Input Interface
Number of Inputs: 1 dedicated full-bridge strain gauge input
Input Type: Differential input for Wheatstone full-bridge sensorsB& R Industrial Automation
Connection: Supports 4-wire and 6-wire (sense leads) configurationsB& R Industrial Automation
Strain Gauge Factor (Measuring Range): Software-configurable 2 to 256 mV/VB& R Industrial Automation
Bridge Excitation Voltage: 5.5 VDC (max. 65 mA)
Sensor Resistance Range: 85 Ω to 5000 Ω
Common-Mode Voltage Range: 0 to 3 VDC
Digital Converter Resolution: 24-bit sigma-delta ADCB& R Industrial Automation
Data Output Rate: Software-configurable 0.1 Hz to 7.5 kHz (0.1 to 7500 samples/sec)B& R Industrial Automation
Input Filter: 3rd-order, 60 dB/octave filter with configurable cutoff (default 5 kHz)B& R Industrial Automation
Input Protection: RC surge protection
3.2 Performance Characteristics
System Compensation: Automatic compensation for gain, offset, and bridge voltage drift
Special Operating Modes:
Synchronous Mode: For synchronized sampling across multiple modules
Multiple Sampling: For enhanced noise reduction and stability
Conversion Time: Dependent on the configured data output rateB& R Industrial Automation
3.3 Electrical & Power Characteristics
Bus Interface: X20 System Backplane
Power Consumption:
Bus Power: 0.01 WB& R Industrial Automation
Internal I/O Power: 0.5 WB& R Industrial Automation
Max. Additional Dissipation (Actuators): +0.36 WB& R Industrial Automation
Isolation: Full galvanic isolation between bus, analog input, and bridge supply
3.4 Physical & Environmental Characteristics
Form Factor: Slim, modular X20 slice I/O module
Width: 12.5 mm (+0.2 mm)
Weight: Approx. 0.035 kg (0.077 lbs)
Mounting: Direct insertion into X20 bus base module (DIN-rail compatible)
Connectors: Requires separate X20TB12 12-pin terminal block
Bus Base Module: Requires separate X20BM11 or X20BM15 bus module
Operating Temperature: -25°C to +60°C (horizontal mount)
Storage Temperature: -40°C to +85°C
Relative Humidity: 5 – 95% RH, non-condensing
Vibration/Shock: Conforms to IEC 60068 standards
Protection Rating: IP20 (front face)
Material: Flame-retardant industrial plastic
3.5 Status Indicators & Diagnostics
Channel LED: 1 LED for input statusB& R Industrial Automation
Module Status LED: Indicates power, run, and error conditionsB& R Industrial Automation
Diagnostic Features:
Comprehensive module run/error diagnosticsB& R Industrial Automation
Open circuit detection for sensor/connection failureB& R Industrial Automation
Real-time input signal status monitoringB& R Industrial Automation
Software-configurable alarm thresholds
4. Key Features & Benefits
Ultra-High Resolution 24-bit ADC: Provides unparalleled precision for micro-strain and low-signal measurements.
Full-Bridge Specialization: Optimized circuit design for direct connection to strain gauge load cells and force sensors.
Flexible Wiring: 4/6-wire support eliminates long-cable resistance errors, ensuring measurement integrity.
Wide Measuring Range: Software-configurable 2–256 mV/V span adapts to various sensor sensitivities.
High-Speed Sampling: Up to 7.5 kHz rate for capturing dynamic force or weight changes.
Advanced Signal Processing: Built-in compensation and filtering ensure stable, drift-free readings.
Industrial Robustness: Galvanic isolation and surge protection safeguard against electrical noise and transients.
Comprehensive Diagnostics: Open-circuit detection simplifies maintenance and reduces downtime.
Seamless X20 Integration: Hot-swappable design for easy installation and expansion.
Hazardous Location Rated: ATEX Zone 2 certification for use in potentially explosive atmospheres.
5. Typical Applications
Precision Weighing Systems: Single/multi-point scales, hopper scales, belt scales, and checkweighers.
Force & Torque Measurement: Material testing machines, press force monitoring, robotics, and assembly tools.
Industrial Automation: Tension control in web handling (paper, film, wire), load monitoring on cranes and lifts.
Test & Measurement: High-resolution data acquisition for structural and materials research.
Process Control: Batching, dosing, and filling systems requiring exact weight measurement.
Hazardous Areas: Weighing applications in chemical, pharmaceutical, and oil & gas facilities (ATEX Zone 2).
6. Compatibility
System Compatibility: Fully compatible with all B&R X20 system controllers and CPUs.
Bus Base: Requires X20BM11 (standard) or X20BM15 (with node switch) bus module.
Terminal Block: Requires X20TB12 12-pin screw terminal block.
Software: Fully configurable via B&R Automation Studio (measurement range, sampling rate, filters, alarms).
7. Reliability & Support
Design Life: Engineered for continuous 24/7 operation in industrial environments.
Warranty: Covered under B&R's standard manufacturer's warranty.
Product Lifecycle: Active, current production with full technical support.
Maintenance: Minimal maintenance; diagnostics enable quick fault identification and resolution.
Get a Quote