Honeywell 51400997-100 (TDC 3000 PLC Gateway Interface Card PLCI)
Description
Model Explanation
51400997-100: Honeywell part number (no delimiter 51400997100)
51400997 = PLCI (PLC Gateway Interface) Gateway Card Series
100 = Standard version, Rev A firmware, LCN standard compatibility
Component Type: PLCI PWA (PLC Gateway Interface Printed Wiring Assembly)
Compatibility System: TDC 3000, TPS, Experion PKS (LCN compatible)
Alternative Model: 51400997-200 (EPLCI Enhanced Version) Technical Specifications
Processor: Special 16-bit communication processor, with a main frequency of 20 MHz
Memory: 128 KB RAM (data cache), 64 KB EPROM (firmware)
Communication interface: 2 independent RS-232/422/485 serial ports (Port1/Port2)
Baud rate: 300 bps ~ 19.2 kbps (jumper configuration)
Protocol support: Modbus RTU, Siemens 3964R, Allen-Bradley DF1, etc.
Power supply: 5 VDC (backplane, ±5%), power consumption ≤ 18 W
Operating temperature: 0°C ~ +60°C (industrial grade)
Storage temperature: -40°C ~ +85°C
Humidity: 5% ~ 95% RH (no condensation)
Size: Standard 19-inch card (3U), 5-slot module
Weight: Approximately 1.1 kg
Certifications: CE, UL, CSA, FM
Interface and Configuration
Backplane interface: LCN cabinet gold fingers, dedicated LCN control bus
Serial port terminals: Port1 (DB9), Port2 (DB9), supports RS-232/422/485
Status indicators: PWR, LCN ACT, PORT1 ACT, PORT2 ACT, FAULT LED
Configuration method: On-board jumpers (baud rate, parity check) + HG software configuration
Redundancy: Supports 1:1 hot redundancy configuration (dual PLCI seamless switching)
Compatibility: Compatible with TDC 3000 LCN full version, compatible with HMPU, HG cards Core function
Protocol Conversion and Data Routing: Achieve mutual conversion between LCN network protocol and PLC serial port protocol. Support DCS reading and writing of PLC registers and coils, and real-time bidirectional data synchronization (delay ≤ 100 ms).
Parallel Communication for Multiple PLCs: Dual serial ports are independently configured, capable of simultaneously connecting 2 different brands of PLCs. Support mixed communication of multiple protocols, without the need for additional gateway devices.
Data Caching and Point Breakpoint Continuation Transmission: 128 KB high-speed cache. Caches data during network interruption, and automatically resumes transmission upon recovery, ensuring data integrity.
System Diagnosis and Alarm: Real-time monitoring of communication status, serial port errors, and LCN network failures. Triggers DCS alarm and records logs when abnormalities occur.
HG Software Integration: Runs based on Hiway Gateway (HG) software, does not require modification of the system kernel, and is compatible with the existing LCN network architecture. Applicable scenarios
System: Honeywell TDC 3000, TPS, Experion PKS (LCN compatible)
Equipment: LCN cabinet, 5-slot equipment module, third-party PLC (Siemens S7, AB CompactLogix, etc.)
Industry: Petrochemicals, thermal power, metallurgy, cement, pharmaceuticals, papermaking
Application: DCS and PLC system integration, old system upgrade, multi-vendor equipment integration, remote equipment monitoring, data acquisition and control
Get a Quote