Honeywell 51309223‑125(MU‑TAMT03)
Description
Model Explanation
51309223-125: Honeywell Material Number (51309223 = TC-specific LLMUX series; 125 = 16-channel standard version)
MU-TAMT03: Module Model
MU = Multiplexer Unit (Multi-channel unit)
TAMT = Thermocouple Analog Multiplexer TC (Thermocouple Analog Multi-channel)
03 = Hardware Version (Rev.03, Industrial Standard Version) Technical Specifications
Channel quantity: 16 differential inputs (mainly TC, compatible with 2 RTD)
Signal type: Thermocouple (B/E/J/K/N/R/S/T types) + 2 RTD (PT100) + mV signal
Resolution: 16 bits (high-precision ADC)
Accuracy: TC: ±0.5°C; RTD: ±0.2°C
Isolation strength: 1500V RMS (channel - system isolation)
Cold junction compensation (CJR): On-board local high-precision CJR (±0.5°C)
Input impedance: >1MΩ (TC/mV dedicated)
Power supply: 24VDC (±10%), UCN backplane power supply
Operating temperature: 0°C ~ +60°C (standard industrial grade)
Storage temperature: -40°C ~ +85°C
Humidity: 5% ~ 95% RH (no condensation)
Size: 135 × 85 × 55 mm
Weight: 0.75 kg
Certifications: CE, UL, CSA
Interfaces and Communications
Field side: 16 gold-plated screw terminals (common for TC/RTD/mV connections)
System side: High-density UCN flat cable (connects LLMUX IOP cards)
Status indicators: PWR (green), READY (green), FAULT (red) LEDs
Configuration: DCS software configuration for TC type, RTD wiring, range, filtering, CJR parameters
Hot-swappable: Supported (online replacement does not affect system operation) Core function
16-channel TC high-precision acquisition + 2-channel RTD multiplexing: Suitable for mainstream thermocouples, also accommodating a few RTD measurement points, with high flexibility
On-board precise cold junction compensation: Local CJR eliminates the cold junction error of thermocouples, ensuring low-temperature measurement accuracy
High input impedance anti-interference: >1MΩ input impedance, compatible with weak TC/mV signals, suppressing industrial environment EMI interference
Full coverage of fault diagnosis: TC open/closed circuit, RTD failure, over-range, power supply abnormal alarm
Compact design easy to install: Small size, light weight, saving space in cabinet layout, convenient wiring Applicable scenarios
Industry: Petrochemicals, Electricity (thermal power / nuclear power), Metallurgy, Glass manufacturing, Heat treatment
Applications: 16-channel thermocouple dense temperature measurement, high-temperature furnaces / reaction vessels / pipeline temperature monitoring, mainly TC with a small amount of RTD mixed measurement points
Compatible systems: Experion PKS (C200/C300), TDC 3000, TPS (UCN network LLMUX IOP matching)