Reliance57403‑G (0‑57403‑G)16‑point 115 VAC high‑power output module
May 30, 2026

Reliance57403‑G (0‑57403‑G)16‑point 115 VAC high‑power output module

The 57403‑G (0‑57403‑G) is a 16‑point 115 VAC high‑power output module manufactured by Reliance Electric (later ABB) for the AutoMax PLC/DCS platform. It is the latest hardware revision in the 57403 family, featuring enhanced surge suppression, higher inrush current tolerance, and improved thermal stability for heavy‑duty inductive/capacitive loads. The module is discontinued, with only refurbished, surplus, or used units available for legacy system maintenance and replacement. Model Interpretation

Description

Product Introduction

The 57403‑G (0‑57403‑G) is a 16‑point 115 VAC high‑power output module manufactured by Reliance Electric (later ABB) for the AutoMax PLC/DCS platform. It is the latest hardware revision in the 57403 family, featuring enhanced surge suppression, higher inrush current tolerance, and improved thermal stability for heavy‑duty inductive/capacitive loads. The module is discontinued, with only refurbished, surplus, or used units available for legacy system maintenance and replacement.

Model Interpretation

  • 57403‑G: Base model; G denotes hardware revision G (latest enhanced revision).

  • 0‑57403‑G: Full AutoMax part number (leading 0 = standard I/O module).

  • 57403: Product family = high‑power 115 VAC output module.

  • ‑G: Revision with upgraded PCB, metal oxide varistor (MOV) protection, higher inrush rating, and extended temperature range; fully backward compatible with ‑D/‑E revisions.

Technical Parameters

  • Channels: 16 independent outputs (0–15).

  • Output Type: Solid‑state, 115 VAC (50/60 Hz).

  • Load Voltage: 70–132 VAC.

  • Rated Current: 2.0 A per channel; max total 32 A.

  • Inrush Current: 10 A peak (10 ms) for inductive loads.

  • Leakage Current: ≤1.5 mA (off‑state).

  • On‑State Resistance: <8 Ω.

  • Response Time: <10 ms.

  • Backplane Power: +5 VDC, ~650 mA.

  • Isolation: 2500 VAC field‑to‑logic; 1500 VAC channel‑to‑channel.

  • Protection: Overcurrent, short‑circuit, thermal shutdown, MOV‑based surge suppression, reverse polarity; self‑recovery after fault.

  • Operating Temperature: ‑10 °C to +70 °C (extended range).

  • Humidity: 5%–95% non‑condensing.

  • Weight: ~1.2 kg.

Interface and Communication Configuration

  • Backplane Interface: Edge connector for AutoMax dedicated backplane bus; provides power and data exchange with CPU.

  • Field Interface: Screw terminals (0–15) with four isolated common groups (C1–C4) (4 outputs per common).

  • Indicators: 16 channel status LEDs + power/fault LED on front panel.

  • Communication: No independent network ports; all I/O data via AutoMax backplane bus.

Core Functions

  • Converts 5 V logic signals from PLC into 115 VAC drive signals for high‑power field devices.

  • Drives motor starters, large solenoids, contactors, heaters, and high‑inrush inductive/capacitive loads.

  • Provides individual channel overcurrent/short‑circuit/surge protection with automatic recovery.

  • Feeds back channel status to CPU for diagnostics and system monitoring.

  • Supports hot swapping in properly configured AutoMax systems.

Application Scenarios

  • Replacement/maintenance of legacy AutoMax PLC/DCS in heavy industry.

  • Process control in metallurgy, paper, chemical, power, and oil/gas sectors.

  • Driving 115 VAC high‑power devices in assembly lines, material handling, and machine tools.

  • Systems requiring extended temperature range, high surge immunity, and high inrush current capability.

Operation and Maintenance Instructions

  • Installation: Power off rack before insertion; align and seat firmly, tighten mounting screws.

  • Wiring: Connect loads to 0–15 and commons to C1–C4; use 14–18 AWG wire, avoid over‑torque.

  • ESD Protection: Use anti‑static wristband/mat when handling; static may damage circuits.

  • Routine Maintenance: Quarterly inspection of terminals for looseness/corrosion; keep clean and dust‑free.

  • Troubleshooting: Check channel LEDs; verify load voltage/wiring before module replacement.

  • Replacement: Replace entire module if internal fault; do not repair PCB.


Get a Quote