Reliance Electric 50V4260 50 HP (37 kW), 480 VAC, 3‑phase AC drive
Description
Product Introduction
Model Interpretation
50 = 50 horsepower
V = GV3000/SE series (Vtac7)
42 = 480 VAC input, heavy‑duty rating
60 = Standard firmware, NEMA 1 enclosure, enhanced I/O
Technical Parameters
Power rating: 50 HP / 37 kW (heavy‑duty)
Input voltage: 380–480 VAC, 3‑phase, 50/60 Hz
Output current: 72 A continuous (heavy‑duty)
Input current: ~78 A
Max output frequency: 200 Hz
Control modes: V/Hz, sensorless vector, closed‑loop vector (encoder feedback)
Enclosure: NEMA 1 (IP20)
Protection: 200% overcurrent, 150% overload (1 min), short‑circuit, ground fault, phase loss
Operating temperature: 0 °C to +45 °C
Software version: Ver. 6.06 / 6.07
Status: Discontinued; available as surplus/refurbished
Interface & Communication
Power terminals: 3‑phase AC in (L1/L2/L3), 3‑phase AC out (U/V/W), DC bus terminals
Control terminals: Start/stop, speed reference (0–10 VDC), fault reset, encoder (A/B/Z), digital I/O
Front panel: Keypad & LED display for setup, monitoring, and diagnostics
Options: RS‑232/485, Profibus‑DP, DeviceNet communication modules
Core Functions
Heavy‑duty vector control: High starting torque (200% at 0.5 Hz) for demanding loads
Auto‑tuning: Motor parameter identification for optimal performance
Speed range: 1:1000 (closed‑loop vector with 1024 PPR encoder)
Dynamic response: 20 Hz bandwidth for rapid load changes
Built‑in PLC: Basic logic functions for standalone operation
Fault logging: 50‑event history with time stamps for troubleshooting
Application Scenarios
Heavy‑duty conveyors: Mining, aggregate, and bulk material handling
Extruders: Plastic, rubber, and food processing machinery
Cranes/hoists: Material handling with precise speed/torque control
Machine tools: High‑power lathes, mills, and grinders
Retrofits: Replacement for legacy GV3000/SE 50 HP drives
Operation & Maintenance
Mount in NEMA 1 enclosure with adequate ventilation; avoid high vibration
Wire per schematic: AC line, motor, control signals, encoder, and DC bus (if used)
Configure motor nameplate data, speed limits, current limits, and control mode via keypad
Regularly inspect cooling fans, heat sinks, and wiring connections; keep drive clean
Discontinued by Reliance Electric; use refurbished units or upgrade to modern AC drives
Get a Quote