1. Product Overview
1.1 Full Part Number
1.2 Product Type
FANUC CNC System Control Board / Industrial CNC PCB Assembly
1.3 Code Definition
A02B: FANUC CNC system series code
0200: Hardware base model code
C081: Configuration version and functional specification code
1.4 Application
Applicable to FANUC CNC machine tools, machining centers and automatic numerical control production equipment.
Used for system core signal processing, peripheral interface connection, data communication and logic control operation.
2. Technical Specifications
Rated Working Voltage: DC 24V ±10%
Operating Ambient Temperature: 0℃ ~ +55℃
Storage Temperature Range: -20℃ ~ +70℃
Relative Humidity: 10% ~ 90%, non-condensing
Installation Type: Standard control cabinet slot plug-in mounting
EMC Grade: Industrial electromagnetic compatibility anti-interference standard
Continuous Operation: Support 24-hour long-term stable running
Insulation Standard: Comply with industrial electronic safety and insulation regulations
3. Main Features
3.1 Adopts industrial-grade circuit design with stable performance and strong anti-electromagnetic interference ability.
3.2 Standard A02B-0200 series overall size, high universality and perfect interchangeability.
3.3 C081 dedicated configuration design, complete interface definition, fully matched with original equipment.
3.4 Built-in over-current, over-voltage and anti-static protection circuits to prevent component damage.
3.5 All components pass strict screening and aging test, low failure rate and long service life.
3.6 Simple installation and wiring, easy disassembly, replacement and daily maintenance.
4. Installation Instructions
4.1 Completely cut off the equipment main power supply before installation and maintenance.
4.2 Take standard anti-static measures to avoid static electricity damaging the circuit board.
4.3 Confirm part number A02B-0200-C081 matches the equipment replacement requirement.
4.4 Clean the cabinet mounting slot, remove dust, metal debris and foreign matters.
4.5 Align the PCB board with the guide slot, insert smoothly into the fixed position.
4.6 Fasten mounting screws evenly; over-tightening is forbidden to avoid board deformation.
4.7 Connect power cables and signal cables strictly according to interface labels.
4.8 Recheck all connection points, close the cabinet door, then carry out power-on test.
5. Operation Precautions
5.1 Only use rated standard power supply; unstable or non-standard voltage input is prohibited.
5.2 Hot plugging and unplugging of the board is strictly forbidden under power-on status.
5.3 Do not operate in environments with heavy dust, corrosive gas, water splash and strong vibration.
5.4 Keep away from high-power inverters and strong electromagnetic interference sources.
5.5 Do not disassemble, modify or replace internal circuits and components without authorization.
5.6 Stop operation and power off immediately in case of system alarm, abnormal signal or startup failure.
6. Maintenance and Storage
6.1 Daily Maintenance
Clean surface dust regularly with dry compressed air; periodically check connector tightness and wire connection status.
6.2 Storage Environment
Store in dry, ventilated, dust-free indoor area without corrosive gas.
6.3 Storage Conditions
Ambient temperature: 5℃ ~ 35℃
Relative humidity: ≤ 85%, no condensation
6.4 Handling Requirements
Avoid static induction, collision, bending and heavy pressure extrusion.
6.5 Shelf Life
12 months under original sealed packaging and standard storage conditions.
7. Quality Statement
7.1 A02B-0200-C081 conforms to FANUC CNC industrial electronic manufacturing standards.
7.2 All products pass full functional test and aging inspection before delivery.
7.3 This manual is applicable to original and compatible replacement parts of A02B-0200-C081.
2. Technical Specifications
Rated Working Voltage: DC 24V ±10%
Operating Ambient Temperature: 0℃ ~ +55℃
Storage Temperature Range: -20℃ ~ +70℃
Relative Humidity: 10% ~ 90%, non-condensing
Installation Type: Standard control cabinet slot plug-in mounting
EMC Grade: Industrial electromagnetic compatibility anti-interference standard
Continuous Operation: Support 24-hour long-term stable running
Insulation Standard: Comply with industrial electronic safety and insulation regulations
3. Main Features
3.1 Adopts industrial-grade circuit design with stable performance and strong anti-electromagnetic interference ability.3.2 Standard A02B-0200 series overall size, high universality and perfect interchangeability.3.3 C081 dedicated configuration design, complete interface definition, fully matched with original equipment.3.4 Built-in over-current, over-voltage and anti-static protection circuits to prevent component damage.3.5 All components pass strict screening and aging test, low failure rate and long service life.3.6 Simple installation and wiring, easy disassembly, replacement and daily maintenance.
4. Installation Instructions
4.1 Completely cut off the equipment main power supply before installation and maintenance.4.2 Take standard anti-static measures to avoid static electricity damaging the circuit board.4.3 Confirm part number A02B-0200-C081 matches the equipment replacement requirement.4.4 Clean the cabinet mounting slot, remove dust, metal debris and foreign matters.4.5 Align the PCB board with the guide slot, insert smoothly into the fixed position.4.6 Fasten mounting screws evenly; over-tightening is forbidden to avoid board deformation.4.7 Connect power cables and signal cables strictly according to interface labels.4.8 Recheck all connection points, close the cabinet door, then carry out power-on test.
5. Operation Precautions
5.1 Only use rated standard power supply; unstable or non-standard voltage input is prohibited.5.2 Hot plugging and unplugging of the board is strictly forbidden under power-on status.5.3 Do not operate in environments with heavy dust, corrosive gas, water splash and strong vibration.5.4 Keep away from high-power inverters and strong electromagnetic interference sources.5.5 Do not disassemble, modify or replace internal circuits and components without authorization.5.6 Stop operation and power off immediately in case of system alarm, abnormal signal or startup failure.
6. Maintenance and Storage
6.1 Daily Maintenance
Clean surface dust regularly with dry compressed air; periodically check connector tightness and wire connection status.
6.2 Storage Environment
Store in dry, ventilated, dust-free indoor area without corrosive gas.
6.3 Storage Conditions
Ambient temperature: 5℃ ~ 35℃Relative humidity: ≤ 85%, no condensation
6.4 Handling Requirements
Avoid static induction, collision, bending and heavy pressure extrusion.
6.5 Shelf Life
12 months under original sealed packaging and standard storage conditions.
7. Quality Statement
7.1 A02B-0200-C081 conforms to FANUC CNC industrial electronic manufacturing standards.7.2 All products pass full functional test and aging inspection before delivery.7.3 This manual is applicable to original and compatible replacement parts of A02B-0200-C081.
Get a Quote