ABB 3AXD50000000753 (AFPS-61C) fan power supply board
May 30, 2026

ABB 3AXD50000000753 (AFPS-61C) fan power supply board

ABB 3AXD50000000753 (AFPS-61C) is a fan power supply board for ABB ACS800 series inverters. It provides stable power to the inverter’s cooling fans and internal control circuits, ensuring reliable heat dissipation and continuous operation of the drive.

Description

Product Introduction

ABB 3AXD50000000753 (AFPS-61C) is a fan power supply board for ABB ACS800 series inverters. It provides stable power to the inverter’s cooling fans and internal control circuits, ensuring reliable heat dissipation and continuous operation of the drive.

Model Interpretation

  • 3AXD50000000753: ABB commercial part number.

  • AFPS-61C: Official type designation (Fan Power Supply Board).

  • Applicable Series: ABB ACS800 series industrial inverters.

Technical Parameters

  • Input Voltage: 100–240 V AC, 50/60 Hz.

  • Output Voltage: 24 V DC (regulated).

  • Output Current: Up to 3 A (for cooling fans and auxiliary circuits).

  • Power Rating: 72 W.

  • Isolation: Input-output isolation for safety.

  • Protection: Overvoltage, overcurrent, short-circuit, overtemperature.

  • Operating Temperature: 0 °C to +55 °C.

  • Storage Temperature: −40 °C to +70 °C.

  • Dimensions: Standard PCB size for ACS800 cabinet mounting.

  • Weight: Approximately 0.8 kg.

  • Origin: Sweden.

Interface and Connection

  • Power Input: AC terminal block (100–240 V AC).

  • DC Output: 24 V DC screw terminals for fans and control circuits.

  • Signal Connections: Auxiliary contacts for fault monitoring.

  • Mounting: Installed inside ACS800 inverter cabinet, connected to backplane.

Core Functions

  • Fan Power Supply: Converts AC input to regulated 24 V DC for inverter cooling fans, maintaining optimal operating temperature.

  • Auxiliary Power: Provides stable 24 V DC for internal control logic and sensors.

  • Fault Protection: Shuts down or limits current during overload, short circuit, or overheating to protect the inverter.

  • Status Monitoring: Supports remote alarm signaling for maintenance diagnostics.

Application Scenarios

  • ABB ACS800 Inverters: Mainly used in medium-voltage and high-power ACS800 drives for fan and auxiliary power.

  • Industrial Drives: Widely applied in power, oil and gas, chemical, metallurgy, and water treatment industries.

  • Critical Cooling Systems: Ensures continuous operation of cooling fans in high-power inverters to prevent overheating.

Operation and Maintenance

  • Installation: Mount vertically in the inverter cabinet; ensure adequate ventilation.

  • Wiring: Use insulated copper cables; verify AC input range and DC output polarity.

  • Routine Check: Inspect for loose connections, dust accumulation, and abnormal noise.

  • Replacement: Disconnect power before replacement; use ESD protection to avoid static damage.

  • Troubleshooting: Check LED indicators (if available) and alarm signals for fault diagnosis.