ABB 1SAP170500R0001(CM575-DN)DeviceNet master communication module
May 29, 2026

ABB 1SAP170500R0001(CM575-DN)DeviceNet master communication module

1SAP170500R0001 is the CM575-DN, a DeviceNet master communication module for the ABB AC500 PLC series. It enables the AC500 CPU to act as a DeviceNet master, connecting up to 63 slave devices such as sensors, actuators, drives, and I/O modules in industrial networks. With a compact DIN‑rail design, pluggable spring terminals, and support for high‑speed DeviceNet communication, it integrates seamlessly into ABB’s modular automation systems for factory and process automation requiring DeviceNet connectivity.

Description

Product Introduction

1SAP170500R0001 is the CM575-DN, a DeviceNet master communication module for the ABB AC500 PLC series. It enables the AC500 CPU to act as a DeviceNet master, connecting up to 63 slave devices such as sensors, actuators, drives, and I/O modules in industrial networks. With a compact DIN‑rail design, pluggable spring terminals, and support for high‑speed DeviceNet communication, it integrates seamlessly into ABB’s modular automation systems for factory and process automation requiring DeviceNet connectivity.

Model Explanation

  • 1SAP170500R0001: Full ABB part number.

  • CM575‑DN: Communication Module, DeviceNet protocol.

  • 170500: CM575 base platform for DeviceNet; R0001: hardware revision.

  • DN: Denotes native DeviceNet master functionality, distinguishing it from CM572 (PROFIBUS DP), CM574 (serial/RCOM), and CM577 (Ethernet) modules in the AC500 lineup.

Technical Parameters

  • Power Supply: 24 V DC (±20%), powered via PLC backplane bus.

  • Power Consumption: Max 2.5 W (typical 290 mA current draw).

  • Communication Protocol: DeviceNet (master mode only).

  • Baud Rate: 125 Kbps, 250 Kbps, 500 Kbps (configurable).

  • Max Slave Nodes: 63 devices per module.

  • Bus Length: Up to 500 m (depends on baud rate and cable type).

  • Isolation: 500 V DC isolation between DeviceNet network and PLC internal bus.

  • Operating Temperature: 0 °C to +60 °C; storage: −40 °C to +70 °C.

  • Protection Class: IP20; certifications: CE, cULus, RoHS.

  • Dimensions: 135 × 28 × 62 mm (H × W × D); weight: ~0.12 kg.

  • Connector: 5‑pin pluggable spring terminal (COMBICON).

  • LED Indicators: PWR, RUN, NET, and ERR for power, module status, network activity, and diagnostics.

Interface & Communication Configuration

  • DeviceNet Master Interface: Single 5‑pin spring terminal port for DeviceNet network connection.

  • PLC Bus Connection: Direct interface with AC500 CPU’s FBP bus for high‑speed internal data exchange.

  • Isolation Design: 500 V DC electrical isolation protects PLC circuitry from network noise and voltage spikes.

  • Software Configuration: Set baud rate, node address, I/O mapping, and slave parameters via ABB Automation Builder; supports EDS file import for third‑party DeviceNet devices.

  • Termination: Requires 120 Ω termination resistors at both ends of the DeviceNet bus.

  • Diagnostics: LED status indicators and system diagnostics enable quick troubleshooting of network faults, slave disconnections, or communication errors.

Core Functions

  • DeviceNet Master Communication: Native master functionality to manage up to 63 DeviceNet slaves, enabling real‑time data exchange and control.

  • High‑Speed Data Transfer: Supports 125–500 Kbps baud rates for fast, deterministic communication in industrial networks.

  • Seamless Integration: Works with ABB AC500 CPUs and third‑party DeviceNet‑compliant devices for flexible system design.

  • Hot‑Swap Support: Can be replaced without powering down the AC500 system, minimizing downtime during maintenance.

  • Robust Diagnostics: Comprehensive LED indicators and software diagnostics simplify network monitoring and fault resolution.

Application Scenarios

  • Factory automation: Automotive, packaging, and material handling lines using DeviceNet for I/O, drives, and sensor networking.

  • Process industries: Water treatment, chemical, and pharmaceutical plants integrating DeviceNet‑based analytical instruments and control devices.

  • Machine building: Standard machinery requiring cost‑effective, high‑speed DeviceNet connectivity for distributed I/O and motion control.

  • Legacy system migration: Upgrading older DeviceNet‑based systems to ABB AC500 PLCs while retaining existing field devices.

  • Industrial networking: Combining with Ethernet (CM577) or PROFIBUS (CM572) modules to build hybrid multi‑protocol networks.

Usage & Maintenance Instructions

  • Mount on TH35‑15 DIN rail adjacent to AC500 CPU; connect to FBP bus via internal backplane connector.

  • Wire DeviceNet network to 5‑pin terminal: CAN_H, CAN_L, GND, V+, and Shield; install 120 Ω termination resistors at bus ends.

  • Configure baud rate, node address, and slave parameters in Automation Builder; import EDS files for third‑party devices.

  • Keep the environment clean, dry, and well‑ventilated; inspect connectors and wiring quarterly for wear, loose connections, or corrosion.

  • No user‑serviceable parts inside; replace the module if LEDs show persistent faults or communication failures occur.


Get a Quote