Yaskawa DF9200471-E0 Power Distribution Control Board
Description
Model Definition
Technical Specifications
Electrical Parameters
Input voltage: 24 V DC ±10%, 5 V DC ±5% from backplane
Fuse rating: 5 A / 24 V DC, overcurrent protection
Power consumption: Approximately 75 W
Signal handling: Interlock, system monitoring, power distribution
Mechanical & Environmental Parameters
Dimensions (W×H×D): 220 mm × 150 mm × 30 mm
Weight: Approximately 1.2 kg
Operating temperature: 0 °C to +55 °C
Storage temperature: -20 °C to +70 °C
Protection class: IP20
Cooling: Natural convection
Interface Configuration
Power connectors: 24 V DC in/out, 5 V DC in/out
Signal connectors: Safety interlock, system status, alarm output
Expansion slots: Standard for XRC/J300 rack mounting
Core Functions
Distributes 24 V DC/5 V DC to internal boards and peripherals
Monitors safety interlock signals for system safety
Provides overvoltage, overcurrent, short-circuit protection
Collects system status and communicates with main CPU for diagnostics
Optimized E0 revision improves anti-interference and long-term reliability
Compatibility
Compatible controllers: Motoman XRC robot, Yasnac J300/J500 CNC
Matching components:
Backplane: DF8203498-B0
Servo board: DF9200414-A0
Operator panel: DF9200271-A0
Common Faults & Maintenance
Common Faults
Power failure: Fuse blow or circuit damage
Interlock error: Signal line fault or contact issue
System shutdown: Overcurrent/voltage anomaly
Maintenance Guidelines
Use ESD protection during handling
Check connectors and fuses regularly
Keep board clean from dust
Replace with exact DF9200471-E0 (Rev E01)
Power off before removal/installation
Application Scenarios
Motoman XRC robot controller power management
Yasnac J300/J500 CNC system power distribution
Industrial automation requiring stable power and signal monitoring
Get a Quote