YASKAWA CACR-SR02AD1FR-Y111 AC SERVOPACK (VS‑800 Series)
May 29, 2026

YASKAWA CACR-SR02AD1FR-Y111 AC SERVOPACK (VS‑800 Series)

Read before installation and operation. High voltage present: Disconnect power before wiring or servicing. Earth ground (PE): Connect securely to protective earth. No live wiring: Do not connect/disconnect cables with power on. Overheat risk: Ensure adequate ventilation; keep ambient 0–45°C. Emergency stop: Wire E‑STOP to disable drive in hazard situations. Discontinued model: This unit is obsolete; use only as replacement.

Description

1. SAFETY INSTRUCTIONS

Read before installation and operation.
  • High voltage present: Disconnect power before wiring or servicing.

  • Earth ground (PE): Connect securely to protective earth.

  • No live wiring: Do not connect/disconnect cables with power on.

  • Overheat risk: Ensure adequate ventilation; keep ambient 0–45°C.

  • Emergency stop: Wire E‑STOP to disable drive in hazard situations.

  • Discontinued model: This unit is obsolete; use only as replacement.


2. GENERAL INFORMATION

2.1 Model Designation

CACR‑SR02AD1FR‑Y111
  • CACR: AC Servo Drive

  • SR: Speed/Position Control SERVOPACK (VS‑800)

  • 02: 0.2 kW (200 W) rated power

  • A: For Yaskawa R‑series motors

  • D: Analog command (±10 VDC)

  • 1: 200 VAC input, analog control

  • F: F‑type 1500 ppr incremental encoder

  • R: Rack‑mount chassis

  • ‑Y111: Special factory configuration (custom I/O, firmware, or coating)

2.2 Ratings

  • Power: 0.2 kW (200 W)

  • Input: 1‑phase 200–230 VAC, 50/60 Hz

  • Output: 3‑phase 0–230 VAC, 1.5 A rated

  • Control: Analog speed (±10 V) / position (pulse train optional)

  • Encoder: 1500 ppr incremental, F‑type

  • Mounting: Rack mount

  • Weight: Approx. 1.2 kg

2.3 Features

  • Compact, high‑efficiency design

  • Analog speed/position control

  • Built‑in regenerative circuit (external resistor optional)

  • Comprehensive protection: overcurrent, overvoltage, undervoltage, overheat, encoder fault

  • LED status display for diagnostics


3. INSTALLATION

3.1 Mechanical

  • Orientation: Vertical mounting only (heat sink down)

  • Clearance: ≥50 mm top/bottom, ≥20 mm sides

  • Ambient: 0–45°C, 40–90% RH (non‑condensing)

  • Storage: −20 to 60°C

3.2 Wiring (No Images)

Main Circuit (Terminals R, S, U, V, W, PE, RB)

  • R, S: AC input 200–230 VAC

  • U, V, W: Motor 3‑phase output

  • PE: Protective earth (green/yellow)

  • RB: Regenerative resistor (optional, 50 W/100 Ω typical)

Control Connector (2CN, 14‑pin)

  • SG: Signal ground (0 V)

  • VREF: ±10 V speed command (10 V = max speed)

  • FWD: Forward run (NPN/PNP, 24 VDC)

  • REV: Reverse run

  • E‑STOP: Emergency stop (normally closed)

  • ALM: Alarm output (open collector, 24 VDC/50 mA)

  • COM: Common for I/O

Encoder Connector (5CN, 9‑pin, F‑type)

  • A, /A: Encoder phase A (differential)

  • B, /B: Encoder phase B (differential)

  • +5 V: Encoder power (150 mA max)

  • GND: Encoder ground

  • SHLD: Cable shield (connect to drive chassis)


4. OPERATION

4.1 Front Panel (LED Display & Keys)

  • LED: 7‑segment display (status, parameters, fault codes)

  • Keys: MODE (select), SET (enter), ↑/↓ (adjust)

4.2 Basic Modes

  1. Speed Control (Default)
    • Apply ±10 V to VREF: +10 V = forward max speed, −10 V = reverse max speed

    • Set speed via parameter n001 (max speed, default 3000 rpm)

  2. Position Control (Optional)
    • Requires pulse train input (A/B or CW/CCW)

    • Set parameters n002 (position gain), n003 (pulse scale)

4.3 Default Parameters (Key)

  • n000: Drive ID = 0

  • n001: Max speed = 3000 rpm

  • n002: Position gain = 100

  • n003: Pulse scale = 1000 ppr

  • n004: Accel time = 200 ms

  • n005: Decel time = 200 ms


5. TROUBLESHOOTING (Fault Codes)

表格
CodeDescriptionCauseRemedy
1OvercurrentShort circuit, overload, motor faultCheck wiring; reduce load; inspect motor
2OvervoltageRegenerative energy too high, surgeAdd regenerative resistor; check input voltage
3UndervoltageLow input voltage, loose terminalsCheck power supply; tighten connections
AEncoder faultCable broken, loose connector, F‑type mismatchInspect encoder cable; reconnect; verify encoder type
FOverheatPoor ventilation, fan fault, overloadClean heat sink; improve airflow; reduce load
b/CInternal faultDrive damageReplace SERVOPACK

6. MAINTENANCE

  • Daily: Check LED status, unusual noise, or overheating

  • Monthly: Clean heat sink/fan; retighten terminal screws

  • Yearly: Test cooling fan; check electrolytic capacitors (life ~5 years)

  • Disposal: Follow local regulations for electronic waste


7. SPECIFICATIONS SUMMARY

  • Model: CACR‑SR02AD1FR‑Y111

  • Series: VS‑800 (CACR‑SR)

  • Power: 0.2 kW

  • Input: 1‑phase 200–230 VAC

  • Output: 3‑phase 0–230 VAC, 1.5 A

  • Control: Analog speed/position

  • Encoder: 1500 ppr incremental (F‑type)

  • Mounting: Rack

  • Status: Discontinued (Yaskawa)


Get a Quote