YASKAWA CACR‑SR02AB2ER(SERVOPACK)
Description
1. SAFETY INFORMATION
High voltage: Risk of electric shock. Disconnect power ≥5 min before wiring/inspection.
Grounding: Always connect PE terminal to protective earth.
Overload: Do not exceed rated torque or duty cycle.
No modification: Unauthorized changes void warranty and may cause fire/injury.
Emergency stop: Provide external E‑stop to cut power immediately.
2. MODEL NUMBER EXPLANATION
CACR‑SR02AB2ER
CACR: AC Servo Drive
SR: Speed/Position Control(SERVOPACK)
02: 0.2 kW(200W)
A: R‑series motor compatible
B: Design revision
2: 200VAC, pulse command(not analog)
E: 1500 ppr incremental encoder
R: Rack‑mount type
3. SPECIFICATIONS
3.1 General
Rated power: 200W
Input: 200–230VAC, 50/60Hz, single‑phase
Output: 3‑phase 0–230VAC, 1.5A(rated)
Control mode: Pulse position command / analog speed(±10V)
Encoder: 1500 ppr(incremental)
Protection: Overcurrent, overvoltage, undervoltage, overheat, encoder error
Ambient temp: 0–45°C(operation), −20–60°C(storage)
Humidity: ≤90% RH(non‑condensing)
3.2 Default Parameters(Factory)
Position loop gain(Kp): 40
Speed loop gain(Kv): 200
Speed loop integral time(Ti): 20 ms
Encoder resolution: 1500 ppr
Pulse input: 1 pulse = 1 encoder count(default)
4. INSTALLATION & WIRING
4.1 Installation
Mounting: Vertical(heatsink down)
Clearance: Top/bottom ≥100 mm, sides ≥50 mm
Cooling: Free airflow; avoid dust/oil mist
4.2 Main Circuit(Terminal Block)
R, S: AC power input(200–230VAC)
U, V, W: Motor output(3‑phase)
PE: Protective earth
RB: Regenerative resistor(connect if needed)
4.3 Control Circuit(2CN / 5CN)
2CN(I/O)
SG: Signal ground
PULS: Pulse command(position)
SIGN: Direction signal(CW/CCW)
FWD/REV: Run direction(photo‑coupler)
E‑STOP: Emergency stop(NC)
ALM: Alarm output(relay, NC/NO)
5CN(Encoder)
A, /A, B, /B: Encoder signals
+5V, GND: Encoder power
5. OPERATION & DISPLAY
5.1 7‑segment LED
Power ON: “0”(normal)
Running: Speed(rpm)or position(pulses)
Alarm: Fault code(1–7, A, B, C, F)
5.2 Basic Operation
Connect power, motor, encoder; verify wiring.
Set parameters(or use defaults).
Apply PULS+SIGN for position control, or ±10V for speed.
Use FWD/REV to start/stop.
Monitor LED for speed/position or alarms.
6. FAULT CODES & TROUBLESHOOTING
| Code | Fault | Probable Cause | Action |
|---|---|---|---|
| 1 | Overcurrent | Short circuit, overload, wiring error | Check U/V/W; reduce load |
| 2 | Overvoltage | Regen energy too high, surge | Add regen resistor; check input |
| 3 | Undervoltage | Voltage drop, loose terminals | Check supply; tighten connections |
| A | Encoder error | Broken wire, loose connector | Check 5CN; reconnect/replace encoder |
| F | Overheat | Poor ventilation, fan failure | Clean heatsink; check fan |
| B/C | System error | Control board fault | Replace drive |
7. MAINTENANCE
Daily: Check LED, no unusual noise/heat.
Monthly: Clean heatsink/fan; tighten wiring.
Annual: Replace cooling fan(if noisy); check capacitors.
Lifespan: Electrolytic capacitors ≈5 years; fan ≈3 years.
8. OFFICIAL ENGLISH MANUAL DOWNLOAD
MET Service(direct PDF) https://metservice.kr/496355(CACR‑SR Manual (English).PDF, 2.08 MB)
ManualsLib https://www.manualslib.com/products/Yaskawa-Servopack-Cacr-Sr02ab2er-14449771.html
Get a Quote