Reliance 45C35(45C-35)
Description
Product Description
Model Number Interpretation
45C: Unified prefix for Reliance AutoMate 45C-series control components.
35: Designates the AutoBus interface head module(120/240 VAC).
Hyphen: 45C-35 is an alternate writing format; both 45C35 and 45C-35 refer to the same product.
Common Revisions: 802803-RN / RW / RX(revision suffixes for hardware updates).
Technical Specifications
Function: AutoBus network interface head(master/slave configurable).
Power Supply: 120/240 VAC, 50/60 Hz.
Max Wiring Distance: 1000 ft(≈305 m)on AutoBus network.
Compatibility: AutoMate 20/20E PLCs, AutoMax DCS, 45C-series I/O racks.
Backplane: Standard 45C-series edge connector(5 VDC from rack).
Indicators: Front-panel LEDs for PWR, ACTIVE, COMM, and FAULT.
Dimensions: ~228.6 × 177.8 × 152.4 mm(9 × 7 × 6 in).
Weight: ~3.18 kg(7 lbs).
Operating Temp: 0°C to +55°C.
Isolation: 500 Vrms between network and backplane.
Interface & Configuration
Installation: Mounts in a standard 45C-series rack(single slot), secured by screws.
Network Port: D-sub or terminal block for AutoBus network wiring(shielded cable required).
Configuration: Set network address(drop number)and baud rate via DIP switches on the front panel.
Front Panel: Status LEDs for power, network activity, communication link, and fault diagnosis.
Core Functions
Acts as a network gateway between local I/O and the AutoBus industrial network.
Transmits/receives real-time control data, status signals, and diagnostic information.
Supports master-slave communication for multi-controller coordination.
Enables remote monitoring and control of field devices via HMI/SCADA.
Detects network faults(open/short, communication errors)and reports to the PLC CPU.
Application Scenarios
Network expansion for AutoMate 20/20E PLC systems.
Legacy AutoMax DCS maintenance in manufacturing, process control, and power industries.
Distributed I/O connectivity across multiple production lines via AutoBus.
Integration of older Reliance systems with modern HMI/SCADA platforms.
Usage & Maintenance
Installation: Power off the rack before insertion; tighten screws and verify backplane connection.
Wiring: Use shielded twisted-pair cable for AutoBus; ground shield at one end only.
Configuration: Set DIP switches for network address and baud rate; verify LED status after power-on.
Routine Check: Inspect LEDs monthly; clean front panel and connectors quarterly.
Safety: Disconnect all power before handling to avoid electric shock and ESD damage.