Reliance 2GU51010
Description
Product Description
Model Number Interpretation
2: Standard industrial drive series
GU: GP‑2000 series
5: 575 VAC voltage class
10: 10 HP rating
Technical Specifications
Rated Motor Power: 10 HP (7.5 kW)
Apparent Power: 12 kVA
Input: 575 VAC ±10%, three‑phase, 50/60 Hz; max 14.5 A
Output: 0–575 VAC, three‑phase; continuous 12 A, max 12 A; frequency 0–400 Hz
Control Mode: Open‑loop V/F (Volts‑per‑Hertz), PWM modulation
Protection: Overcurrent, overvoltage, undervoltage, overtemperature, short‑circuit, ground fault, electronic motor overload
Enclosure: NEMA 1 (indoor, general purpose)
Ambient Temperature: -10 °C to +50 °C
Dimensions (H×W×D): approx. 470 × 320 × 230 mm
Weight: approx. 22 kg (48.5 lbs)
Certifications: UL 508C, CE, IEC 61800‑5‑1, CSA certified
Short‑Circuit Rating: 25,000 A (symmetrical RMS)
Interface and Communication Configuration
Power Terminals: Three‑phase input, motor output, DC bus braking connection
Control Terminals: ±10 V analog input (speed reference); 24 VDC digital I/O for start/stop, fault reset, jog operation, multi‑speed selection
Communication: Reliance proprietary protocol; no standard fieldbus (e.g., Modbus, Profibus)
Operator Interface: Built‑in keypad with 7‑segment LED display for parameter setup, status monitoring, and fault code readout
Encoder Interface: None (open‑loop control only)
Core Functions
Stable V/F speed regulation for 10 HP three‑phase AC motors
Energy saving for variable‑torque loads (fans, pumps)
Electronic reversing: reverse from any motor speed without contactors
Automatic/manual torque boost for heavy starting loads
Three preset speeds selectable via digital inputs
Adjustable current limit: 50–100% of rated output current
57 password‑protected programmable parameters; non‑volatile memory retains settings during power loss
Real‑time status monitoring and fault code logging for quick diagnostics
Compatibility with external braking resistors for rapid deceleration
Built‑in RFI/EMI filters for reduced electrical interference
Application Scenarios
Medium industry: Conveyors, packaging machines, assembly lines, mixers, extruders
HVAC & process: Large fans, water pumps, cooling towers, agitators
Material handling: 10 HP motor‑driven conveying, lifting, and hoisting equipment
Legacy automation: Direct replacement for GP‑2000 series drives in existing 575 VAC systems
Usage and Maintenance Instructions
Install in a well‑ventilated cabinet; maintain minimum 50 mm clearance around the drive for heat dissipation
Use shielded cables for power and control wiring; tighten all terminals to specified torque
Verify input voltage before powering on; energize control circuit first, then main power
Set parameters per motor nameplate (voltage, current, base frequency, overload)
Quarterly maintenance: Inspect terminals for looseness or overheating, clean internal dust, check cooling fan operation
Before inspection/service: Disconnect all power and wait 5 minutes for DC bus capacitors to fully discharge
Avoid operating in condensing humidity or corrosive environments; keep ambient temperature within -10–50 °C
Get a Quote