Reliance 2GU42001
Description
Product Description
Model Number Interpretation
2: Standard industrial drive series
GU: GP‑2000 series, 460 VAC voltage class
42001: 4 = 460 VAC; 2001 = 1 HP; hardware revision 01
Technical Specifications
Rated Motor Power: 1 HP (0.75 kW), ¼–1 HP range
Apparent Power: 2 kVA
Input: 460 VAC ±10%, three‑phase, 50/60 Hz; max 2.5 A
Output: 0–460 VAC, three‑phase; continuous 2.1 A, max 2.1 A; frequency 0–400 Hz
Control Mode: Open‑loop V/F (Volts‑per‑Hertz)
Protection: Overcurrent, overvoltage, undervoltage, overtemperature, short‑circuit, ground fault
Enclosure: NEMA 12 (dust‑tight, drip‑proof, IP54 equivalent)
Ambient Temperature: -10 °C to +50 °C
Dimensions (H×W×D): approx. 408 × 256 × 202 mm
Weight: approx. 13 kg
Certifications: UL 508C, CE, IEC 61800‑5‑1
Interface and Communication Configuration
Power Terminals: Three‑phase input, motor output, DC bus braking connection
Control Terminals: ±10 V analog input (speed reference); 24 VDC digital I/O for start/stop, fault reset, jog operation
Communication: Reliance proprietary protocol; no standard fieldbus
Operator Interface: Built‑in keypad with 7‑segment LED display for parameter setup and fault code readout
Encoder Interface: None (open‑loop only)
Core Functions
Stable V/F speed regulation for 1 HP three‑phase AC motors
Energy saving for variable‑torque loads (small fans, pumps)
Electronic reversing: reverse from any motor speed without contactors
Automatic/manual torque boost for light starting loads
Three preset speeds selectable via digital inputs
Adjustable current limit: 50–100% of rated output current
57 password‑protected programmable parameters; non‑volatile memory retains settings during power loss
Real‑time status monitoring and fault code logging for quick diagnostics
Built‑in RFI/EMI filters for reduced electrical interference
Application Scenarios
Light industry: Small conveyors, packaging machines, assembly lines
HVAC & process: Small fans, water pumps, cooling equipment
Material handling: 1 HP motor‑driven conveying and lifting equipment
Legacy automation: Direct replacement for GP‑2000 series drives in existing systems
Usage and Maintenance Instructions
Install in a well‑ventilated cabinet; maintain minimum 50 mm clearance around the drive for heat dissipation
Use shielded cables for power and control wiring; tighten all terminals to specified torque
Verify input voltage before powering on; energize control circuit first, then main power
Set parameters per motor nameplate (voltage, current, base frequency)
Quarterly maintenance: Inspect terminals, clean internal dust, check for overheating signs
Before inspection/service: Disconnect all power and wait 5 minutes for DC bus capacitors to fully discharge
Suitable for mild industrial environments; avoid condensing humidity or corrosive conditions