Reliance 2GU41002
Description
Product Description
Model Number Interpretation
2: Standard industrial drive series
GU: GP‑2000 series, 460VAC input platform
41002: 2HP power rating, hardware revision 02
Technical Specifications
Motor Power: 2 HP (1.5 kW), 2.7 kVA
Input Voltage: 460 VAC ±10%, three‑phase, 50/60 Hz, 4.2 A max
Output Voltage: 0–460 VAC, three‑phase, 0–400 Hz, 3.5 A max
Control Modes: V/F (Volts/Frequency) control
Protection: Overcurrent, overvoltage, undervoltage, overtemperature, short‑circuit, ground fault
Operating Temp: 0 °C to +45 °C
Mounting: Panel‑mount (NEMA 1 enclosure)
Weight: ~6.8 kg (15 lbs)
Dimensions: 220 × 150 × 120 mm (H×W×D)
Interface and Communication Configuration
Power Terminals: Main AC input, motor output, DC bus braking terminals
Control I/O: ±10 V analog input (speed reference), 24 VDC digital I/O (start/stop, fault reset, jog)
Communication: Reliance proprietary protocol (no standard fieldbus ports)
Indicators: LED status lights (power, run, fault); 7‑segment display for fault codes and parameters
Feedback: No encoder port (sensorless V/F control only)
Core Functions
Precision Speed Control: Stable speed regulation for 2HP three‑phase AC motors via V/F control
Energy Efficiency: Optimizes power consumption for variable‑torque loads
Dynamic Braking: Supports external brake resistor for rapid deceleration
Fault Diagnostics: Real‑time monitoring with fault code logging for quick troubleshooting
Parameter Programming: Onboard display for configuration of acceleration/deceleration, limits, and I/O
Application Scenarios
Light‑to‑Medium Manufacturing: Conveyor lines, packaging machinery, assembly equipment
HVAC & Process: Medium‑sized fans, pumps, and agitators requiring variable‑speed control
Material Handling: Conveyors and lift equipment with 2HP AC motors
Legacy System Upgrades: Direct replacement for older Reliance GP‑2000 drives
Usage and Maintenance Instructions
Installation: Mount in a clean, well‑ventilated cabinet; allow 50 mm clearance for airflow
Wiring: Use shielded cables for motor/control signals; torque terminals to 1.2 N·m; verify input voltage before power‑up
Operation: Power on control circuit first, then main power; set parameters per motor nameplate
Maintenance: Inspect connections quarterly; clean heat sink/filters semi‑annually
Safety: Disconnect all power and wait 5 minutes for DC bus capacitors to discharge before service
Get a Quote