Reliance 2EC4075
Description
Product Description
Model Number Interpretation
2: Standard industrial drive series
EC: FlexPak VS AC drive platform
4075: 460V input, 75 HP power rating, hardware revision 75
Alternate PN: 892.68.10 C (OEM part number)
Technical Specifications
Motor Power: 75 HP (55 kW)
Input Voltage: 460 VAC ±10%, 3-phase, 50/60 Hz
Output Voltage: 0–460 VAC, 3-phase, 0–400 Hz
Rated Current: 90 A continuous
Control Modes: V/F (Volts/Frequency), sensorless vector
Protection: Overcurrent, overvoltage, undervoltage, overtemperature, short-circuit, ground fault
Operating Temp: 0 °C to +45 °C
Mounting: Floor-standing or panel-mount
Weight: ~68 kg (150 lbs)
Dimensions: 450 × 350 × 200 mm (H×W×D)
Interface and Communication Configuration
Power Terminals: Main AC input, motor output, DC bus braking terminals
Control I/O: ±10 V analog input (speed reference), 24 VDC digital I/O (start/stop, fault reset, jog)
Communication: Supports Reliance proprietary protocol; optional DeviceNet/Profibus DP modules for PLC integration
Feedback: Optional encoder port for closed-loop speed control
Indicators: LED status lights (power, run, fault); 7-segment display for fault codes and parameters
Core Functions
Precision AC Motor Control: Regulates speed, torque, and direction for 75 HP 3-phase AC motors
V/F & Sensorless Vector Control: Optimizes efficiency for fans, pumps, conveyors, and extruders
Dynamic Braking: Integrated DC bus braking for rapid deceleration (optional external brake resistor)
Fault Diagnostics: Real-time monitoring with fault code logging (overtemp, overcurrent, etc.)
Parameter Programming: Onboard display or PC software for configuration of acceleration/deceleration, limits, and I/O
Application Scenarios
Factory Automation: Conveyor lines, assembly stations, packaging machinery
Process Industry: Pumps, fans, mixers, and extruders requiring variable-speed control
Material Handling: Cranes, hoists, and lift equipment with 75 HP AC motors
Legacy System Upgrades: Direct replacement for older Reliance FlexPak VS drives in modernized lines
Usage and Maintenance Instructions
Installation: Mount in a clean, well-ventilated cabinet; allow 100 mm clearance for airflow
Wiring: Use shielded cables for motor/control signals; torque terminals to 1.5 N·m; verify input voltage before power-up
Operation: Power on control circuit first, then main power; set parameters per motor nameplate
Maintenance: Inspect connections quarterly; clean heat sink/filters semi-annually; check brake resistor condition
Safety: Disconnect all power and wait 5 minutes for DC bus capacitors to discharge before service
Get a Quote