Reliance 27106-27S
May 28, 2026

Reliance 27106-27S

The 27106-27S is a 27 Ω standard-duty dynamic brake interface module for Reliance Electric GV3000/SE series AC drives. It connects the drive’s DC bus to external braking resistors, dissipating regenerative energy during deceleration. The S suffix stands for Standard (vs. R=Regular, X=Enhanced high-frequency). Obsolete OEM part; only surplus/refurbished units support legacy systems.

Description

Product Description

The 27106-27S is a 27 Ω standard-duty dynamic brake interface module for Reliance Electric GV3000/SE series AC drives. It connects the drive’s DC bus to external braking resistors, dissipating regenerative energy during deceleration. The S suffix stands for Standard (vs. R=Regular, X=Enhanced high-frequency). Obsolete OEM part; only surplus/refurbished units support legacy systems.

Model Number Interpretation

  • 27106: Base part number for GV3000 brake interface module.

  • 27: 27 Ω nominal braking resistance.

  • S: Standard duty (general-purpose, low-to-medium cycling).

Technical Specifications

  • Resistance: 27 Ω (±5%).

  • Power Rating: 1.2 kW continuous; 4 kW peak (10% duty cycle).

  • DC Bus Voltage: 380–460 VAC input (540–650 VDC bus).

  • Switching Element: Wearless transistor switch (terminals 1(−)/2(+)).

  • Control Logic: Closes when DC bus >50 V and braking current =0; opens during active braking.

  • LED Indicator: Right LED ON when braking current (IB) >0.

  • Enclosure: Open-frame PCB, panel-mount.

  • Operating Temperature: 0°C to +50°C.

  • Weight: ~0.5 kg (1.1 lbs).

Interface & Wiring

  • DC Bus Terminals: Connect to drive’s DC+ / DC−.

  • Resistor Terminals: 1(−) / 2(+) for external 27 Ω braking resistor.

  • Control Signal: Tied to drive’s braking logic (no external wiring needed).

  • LED Status: IB>0 (braking active) → ON; IB=0 → OFF.

Core Functions

  • Regenerative Energy Dissipation: Converts motor regenerative energy to heat via external resistors, preventing DC bus overvoltage.

  • Smooth Deceleration: Enables controlled stops for moderate-inertia loads (conveyors, pumps).

  • Overvoltage Protection: Shunts excess DC bus voltage during deceleration, safeguarding drive components.

  • Status Indication: LED provides visual braking status for troubleshooting.

Compatibility

  • Drive Series: GV3000/SE (Sensorless Enhanced), VTAC7 (HVAC).

  • Drive Models: 25V4160, 25G4160, 25G4260, 3V4160, etc.

  • Input Voltage: 380–460 VAC three-phase.

Installation & Maintenance

  • Mounting: Secure to panel near drive; allow 50 mm clearance for airflow.

  • Wiring: Use 14–16 AWG stranded wire for DC bus/resistor connections; torque terminals to 1.2 N·m.

  • Pre-Power Check: Verify resistor resistance (27 Ω ±5%); check for short circuits.

  • Maintenance: Inspect terminals annually for looseness/corrosion; clean dust from PCB.

  • Safety: Disconnect drive power and wait 5 minutes for DC bus discharge before service.

Get a Quote