Reliance Electric 1DB5010C
Description
Product Description
Model Number Interpretation
1: First‑generation dynamic braking platform
DB: Dynamic Braking unit
5: 200/230VAC voltage class (three‑phase)
010: 10HP power rating (compatible with 10HP drives)
C: Chassis (open‑frame) version, global market
Technical Specifications
Input Voltage: Three‑phase 200/230VAC ±10%, 50/60Hz
Power Rating: 10HP (7.5kW), continuous braking duty
Braking Resistor: Internal high‑power resistor optimized for 10HP motor deceleration
Enclosure: Chassis (open‑frame), IP00 (indoor use only)
Protection: Overvoltage, overcurrent, overtemperature, short‑circuit, ground fault protection
Ambient Conditions: 0–45°C, 5%–95% RH (non‑condensing)
Weight: Approximately 15.9kg (35lb)
Certifications: UL, CSA listed
Interface and Communication Configuration
Power Terminals: L1/L2/L3 (three‑phase input from drive DC bus), PE (protective earth)
Control Terminals: Braking enable input (dry contact from drive), fault output relay (250VAC/5A for overtemp/overvoltage)
Communication: No onboard communication ports; hardwired interlock with drive only
Indicators: Two LEDs; green for power/standby, red for braking active/fault
Core Functions
Absorbs regenerative energy from 10HP motors during rapid deceleration or overhauling loads, preventing drive DC bus overvoltage faults
Reduces motor stopping time significantly compared to coast‑to‑stop
Internal braking resistors eliminate need for external resistor banks, simplifying installation and wiring
Seamless integration with Reliance SP500/GP‑1200 series 200/230VAC 10HP drives
Comprehensive thermal and electrical protection safeguards the unit and connected drive
Application Scenarios
10HP conveyors, cranes, hoists, mixers, and fans requiring fast, controlled stopping
Overhauling load applications (e.g., inclined conveyors, vertical lifts) using 200/230VAC three‑phase power
Retrofit projects for legacy Reliance drive systems needing enhanced braking performance
Light‑to‑medium manufacturing, commercial HVAC, and material handling systems
Usage and Maintenance Instructions
Mount vertically in a clean, dry, well‑ventilated indoor area with 200mm clearance top/bottom for cooling airflow; install in a protective enclosure if exposed to dust or moisture
Use rated copper conductors for power wiring; separate power and control cables to minimize EMI
Connect braking enable signal from drive to ensure coordinated operation
Inspect all terminals and wiring quarterly for looseness, corrosion, or overheating signs
Disconnect all power before cleaning; use a dry cloth only—avoid liquids or chemical cleaners
Monitor LED indicators during operation; resolve red fault conditions before restarting the system
Avoid static discharge when handling; do not disassemble the unit without professional guidance
Store spare units in a cool, dry, dust‑free environment