Reliance Electric 1AC5005C
Description
Product Description
Model Number Interpretation
1: First‑generation GP‑1200 series platform
AC: AC variable‑speed drive
5: 200/230VAC voltage class
005: 5HP power rating
C: Chassis (open‑frame) version, 200/230VAC dual input, global market
Technical Specifications
Input: Three‑phase 200/230VAC ±10%, 50/60Hz; maximum input current 16.7A; input KVA 6.6kVA
Output: Three‑phase 0–230VAC; maximum output current 14.2A; rated motor current 13.5A
Power: 5HP (3.7kW) continuous
Control: Open‑loop V/Hz; speed ratio 20:1; output frequency 0–400Hz; variable torque curves and torque boost
Enclosure: Chassis (open‑frame), IP00 (indoor use only, requires additional enclosure)
Protection: Overcurrent, overvoltage, undervoltage, overtemperature, short circuit, ground fault, motor stall, line transient protection
Ambient: 0–45°C, 5%–95% RH (non‑condensing)
Weight: Approximately 11.3kg (25lb)
Interface and Communication Configuration
Power Terminals: L1/L2/L3 (three‑phase input), U/V/W (motor output), PE (protective earth)
Control Terminals: Digital inputs for start/stop, forward/reverse, fault reset; analog input 0–10VDC for speed reference; relay output for fault indication (250VAC/5A)
Communication: No onboard communication ports; hardwired control only
Indicators: Two LEDs; green for power/run, red (IET) for drive fault
Core Functions
Open‑loop V/Hz control with adjustable torque curves and torque boost for reliable starting and steady‑state operation
Dual 200/230VAC input optimized for global and Asian power grids
0–10VDC analog speed input compatible with potentiometers and PLCs
Comprehensive electrical and thermal protection safeguards drive and motor
Direct drop‑in replacement for legacy 1AC series chassis drives, ensuring compatibility with existing wiring and control schemes
Application Scenarios
Small‑to‑medium conveyors, fans, pumps, mixers, and processing machinery with 5HP motors in 200/230VAC regions
Light manufacturing, commercial HVAC, and ventilation systems operating on 200/230VAC three‑phase power
Retrofit and maintenance of older industrial and commercial AC drive installations with chassis‑style requirements
Usage and Maintenance Instructions
Mount vertically in a clean, dry, well‑ventilated indoor area with adequate clearance for cooling airflow; install in a protective enclosure if exposed to dust or moisture
Use rated copper conductors; separate power and control cables to minimize electromagnetic interference
Inspect all connections before power‑up; check terminals and wiring periodically for looseness or corrosion
Disconnect power before cleaning; use a dry cloth only—do not use liquids or chemical cleaners
Routinely monitor heat sinks and terminals for signs of overheating
Diagnose faults via onboard LED indicators; resolve all issues before restarting the drive
Avoid static electricity discharge; do not disassemble the unit without professional guidance
Store spare units in a cool, dry, dust‑free environment
Get a Quote