Reliance Electric 14C312
Description
Product Description
Model Definition
14: 14C series (Minpak+ DC drives)
C: Motor Control (DC drive category)
312: Power rating & config (10HP, 230/460VAC input)
Technical Specifications
Input: Three-phase AC, 230/460VAC (selectable), 50/60Hz
Output: DC armature (0–460VDC), DC field (fixed/adjustable)
Power Rating: 10HP (7.5kW) @ 460VAC
Control Modes: Open-loop voltage; closed-loop speed (tach feedback)
Protection: Overcurrent, overvoltage, undervoltage, overtemperature, short circuit, ground fault
Ambient: 0–55°C, 5–95% RH (non-condensing)
Mounting: Panel-mount (vertical installation required)
Interface & Wiring
Power Terminals: L1/L2/L3 (3-phase in), A+/A- (armature out), F+/F- (field out), PE (ground)
Control Terminals: Start/stop, forward/reverse, 0–10VDC speed ref, tach feedback, fault reset
Communication: No onboard network port; hardwired analog/digital control only
Core Functions
Precision Speed Regulation: Dual-loop (speed+current) control for stable speed under variable loads
High Torque Density: Strong starting/low-speed torque for 10HP heavy-duty loads
Integrated Protection: Fault shutdown/limiting to safeguard drive and motor
Potentiometer Adjustment: Onboard pots for max speed, current limit, gain, field weakening
Application Scenarios
Machine Tools: Lathes, mills, grinders needing 10HP DC control
Material Handling: Conveyors, small cranes/hoists with high starting torque
Process Industry: Mixers, fans, pumps with variable speed demands
Legacy Retrofit: Direct replacement for old Reliance Minpak+ 14C series drives
Usage & Maintenance
Usage
Install vertically on rigid panel; ≥100mm clearance around for cooling
Wire power/motor/control cables per labels; ensure reliable grounding
Set parameters (max speed, current limit) via onboard potentiometers
Jog test to verify motor rotation before full-load operation
Avoid continuous overload; operate within rated current/voltage
Maintenance
Every 3–6 Months: Inspect chassis, cables, terminals for damage/loose connections
Cleaning: Disconnect power; wipe dust with dry cloth (no liquid cleaners)
Annual Checks: Retighten terminals; clean heat sink fins to prevent overheating
Static Protection: Internal ESD-sensitive components; do not open chassis without proper grounding
Storage: Spare units in cool, dry, dust-free environment
Get a Quote