8BVI0220HWS0.000-1 Detailed Product Description
Description

8BVI0220HWS0.000-1 Detailed Product Description
1. Product Overview
2. Basic Information
Model: 8BVI0220HWS0.000-1
B&R ID Code: 0xA16CB& R Industrial Automation
Series: ACOPOSmulti
Type: Single‑axis Inverter Module, High Voltage, Wall Mount
Mounting: Wall mountingB& R Industrial Automation
Expansion Slots: 2 (for ACOPOSmulti plug‑in modules)B& R Industrial Automation
Key Features: Dynamic Node Allocation (DNA), integrated Safe Stop, motor brake & temperature sensor interfacesB& R Industrial Automation
Certifications: CE, UKCA, cULus (E225616), EAC, KC, Functional Safety (openSAFETY)B& R Industrial Automation
3. Electrical Specifications
3.1 DC Bus Connection
Nominal Voltage: 750 VDCB& R Industrial Automation
Operating Range: 260–800 VDC
Continuous Power Consumption: 16.2 kWB& R Industrial Automation
DC Bus Capacitance: 270 µF
3.2 24 VDC Auxiliary Supply
Input Voltage: 25 VDC ±1.6%
Input Capacitance: 23.5 µF
Max Power Consumption: 21 W + slot loads + 24V output + brake power
24 VDC Output: 2 channels
Output Regulation:
260–315 VDC bus: 25 VDC × (UDC/315)
315–800 VDC bus: 24 VDC ±6%
Fuse: 400 mA slow‑blow electronic, auto‑reset
Undervoltage Threshold: 24 VDC +0% / −4%
3.3 Motor Drive Parameters
Continuous Power: 16 kWB& R Industrial Automation
Continuous Current: 22 AeffB& R Industrial Automation
Peak Current: 55 AeffB& R Industrial Automation
Switching Frequency: Default 5 kHz; optional 10 kHz / 20 kHz
Max Output Frequency: 598 Hz
Current Derating:
10 kHz: 0.4 A/K (starts at 31°C)B& R Industrial Automation
20 kHz: 0.31 A/K (starts at -16°C)B& R Industrial Automation
Altitude Derating: 2.2 Aeff per 1000 m above 500 mB& R Industrial Automation
Max Motor Cable Length:
5/10 kHz: 25 m
20 kHz: 10 m
Insulation Stress: Compliant with IEC TS 60034-25:2004 Curve A
3.4 Motor Holding Brake Interface
Output Voltage: 24 VDC +5.8% / −0%
Continuous Current: 4.2 A
Max Internal Resistance: 0.15 Ω
Demagnetization Voltage: ~30 V
Max Demagnetization Energy: 3 Ws
Max Switching Frequency: 0.5 Hz
Protection: Overload/short‑circuit, open‑circuit, undervoltage monitoring
3.5 Control & Digital Interfaces
Enable Inputs: 2 channels, Sink type, 24 VDC (max 30 V)
Threshold: Low <5 V; High >15 V
Delay: OFF ≤20.5 ms; ON ≤100 µs
Trigger Inputs: 2 channels, Sink type, 24 VDC
Delay: Rising 52 µs ±0.5 µs; Falling 53 µs ±0.5 µs
Temperature Sensor Input: 1 channel (500 Ω–5 kΩ resistive)
Standby Power: 11.3 WB& R Industrial Automation
Discharge Capacitance: 0.22 µFB& R Industrial Automation
4. Mechanical Specifications
Dimensions (W × H × D): 106.5 mm × 317 mm × 263 mm (wall mount)B& R Industrial Automation
Weight: Approx. 5.2 kgB& R Industrial Automation
Protection Class: IP20 (EN 60529)B& R Industrial Automation
Pollution Degree: 2 (non‑conductive)B& R Industrial Automation
Overvoltage Category: III (EN 61800-5-1)B& R Industrial Automation
5. Environmental Conditions
5.1 Temperature
Operating: 5–40°C (rated); up to 55°C (with derating)
Storage: −25–55°C
Transport: −25–70°C
5.2 Humidity
Operating: 5%–85% RH (non‑condensing)
Storage: 5%–95% RH (non‑condensing)
Transport: Max 95% RH at 40°C (non‑condensing)
5.3 Mounting & Altitude
Allowed Orientation: Vertical hanging, horizontal face‑up
Forbidden: Horizontal side mounting
Rated Altitude: 0–500 m
Max Altitude: 4000 m (with derating)B& R Industrial Automation
6. Interface & Terminal Assignment
X1 (Control): Enable, brake, and digital signal terminals
X2 (24 VDC): Auxiliary power input and output
X3 (Encoder): Plug‑in module interface (e.g., EnDat, HIPERFACE)
X4 (Brake/Temp): Motor brake and temperature sensor connection
X5 (Motor Power): U/V/W/PE; 0.25–10 mm² wire range
7. LED Status Indicators
RDY (Green): Module ready; flashes if not ready (undervoltage, overtemperature)
RUN (Orange): Power stage enabled, axis active
ERR (Red): Fault (overload, short circuit, overtemp)
POWERLINK: Link/activity status
24V (Green): Auxiliary power normal
8. Protection & Safety Functions
Motor Protection: Overload, short circuit, earth fault
Thermal Protection: IGBT/heat sink overtemperature; motor temp monitoring
Voltage Protection: DC bus over/undervoltage; 24 VDC undervoltage
Safety: Integrated Safe Stop, safe standstill (compliant with EN 61800-5-2)
Brake Protection: Overload, open/short circuit, undervoltage detection
9. Accessories
9.1 Mandatory
Terminal Block Set: 8BZVI0220S0.000-1A
9.2 Optional
Plug‑in Modules: EnDat 2.2 (8BAC0120.001-2), HIPERFACE (8BAC0121.000-1), resolver (8BAC0122.000-1), etc.
Fan Module: 8BXF002.0000-00
Shield Kits: 8SCS000.0000-00, 8SCS002.0000-00
Cables: POWERLINK/Ethernet (X20CA0E61.00020–X20CA0E61.00100)
10. Typical Applications
Heavy‑duty CNC machine tools and machining centers
Automated assembly and production lines with high load requirements
Packaging, printing, and textile machinery with high‑speed operation
Logistics positioning and conveying systems with high torque demands
High‑precision single‑axis motion control for industrial robots and machine tools