8BVI0110HWS0.000-1 Detailed Product Description
May 13, 2026

8BVI0110HWS0.000-1 Detailed Product Description

8BVI0110HWS0.000-1 Detailed Product Description 1. Product Overview The 8BVI0110HWS0.000-1 is a single-axis high‑voltage servo inverter module from B&R’s ACOPOSmulti series, designed for wall mounting. It delivers 11 kW continuous power with 15.1 A continuous current, integrating a power inverter, motor brake control, and comprehensive safety functions. Engineered for high‑precision motion control in industrial automation, it suits standalone or multi‑axis machines requiring dynamic performance and compact installationB& R Industrial Automation.

Description

贝加莱16.jpg

8BVI0110HWS0.000-1 Detailed Product Description

1. Product Overview

The 8BVI0110HWS0.000-1 is a single-axis high‑voltage servo inverter module from B&R’s ACOPOSmulti series, designed for wall mounting. It delivers 11 kW continuous power with 15.1 A continuous current, integrating a power inverter, motor brake control, and comprehensive safety functions. Engineered for high‑precision motion control in industrial automation, it suits standalone or multi‑axis machines requiring dynamic performance and compact installationB& R Industrial Automation.

2. Basic Information

  • Model: 8BVI0110HWS0.000-1B& R Industrial Automation

  • B&R ID Code: 0x270EB& R Industrial Automation

  • Series: ACOPOSmultiB& R Industrial Automation

  • Type: Single‑axis Inverter Module, High Voltage, Wall MountB& R Industrial Automation

  • Mounting: Wall mountingB& R Industrial Automation

  • Expansion Slots: 2 (for ACOPOSmulti plug‑in modules)B& R Industrial Automation

  • Key Features: Dynamic Node Allocation (DNA), integrated Safe Stop, motor brake & temperature sensor interfacesB& R Industrial Automation

  • Certifications: CE, UKCA, cULus (E225616), KC, Functional Safety (openSAFETY)B& R Industrial Automation

3. Electrical Specifications

3.1 DC Bus Connection

  • Nominal Voltage: 750 VDCB& R Industrial Automation

  • Operating Range: 260–800 VDCB& R Industrial Automation

  • Continuous Power Consumption: 11.2 kWB& R Industrial Automation

  • DC Bus Capacitance: 165 µF

3.2 24 VDC Auxiliary Supply

  • Input Voltage: 25 VDC ±1.6%

  • Input Capacitance: 23.5 µF

  • Max Power Consumption: 12 W + slot loads + 24V output + brake power

  • 24 VDC Output: 2 channels

  • Output Regulation:

    • 260–315 VDC bus: 25 VDC × (UDC/315)

    • 315–800 VDC bus: 24 VDC ±6%

  • Fuse: 250 mA slow‑blow electronic, auto‑reset

  • Undervoltage Threshold: 24 VDC +0% / −4%B& R Industrial Automation

3.3 Motor Drive Parameters

  • Continuous Power: 11 kWB& R Industrial Automation

  • Continuous Current: 15.1 AeffB& R Industrial Automation

  • Peak Current: 37.7 Aeff

  • Switching Frequency: Default 5 kHz; optional 10 kHz / 20 kHz

  • Max Output Frequency: 598 Hz

  • Current Derating:

    • 10 kHz: 0.2 A/K (starts at 49°C)

    • 20 kHz: 0.13 A/K (starts at 4°C)

  • Altitude Derating: 1.51 Aeff per 1000 m above 500 m

  • Max Motor Cable Length:

    • 5/10 kHz: 25 m

    • 20 kHz: 10 m

  • Insulation Stress: Compliant with IEC TS 60034-25:2004 Curve A

3.4 Motor Holding Brake Interface

  • Output Voltage: 24 VDC +5.8% / −0%

  • Continuous Current: 1.1 A

  • Max Internal Resistance: 0.5 Ω

  • Demagnetization Voltage: ~30 V

  • Max Demagnetization Energy: 1.5 Ws

  • Max Switching Frequency: 0.5 Hz

  • Protection: Overload/short‑circuit, open‑circuit, undervoltage monitoring

3.5 Control & Digital Interfaces

  • Enable Inputs: 2 channels, Sink type, 24 VDC (max 30 V)B& R Industrial Automation

    • Threshold: Low <5 V; High >15 VB& R Industrial Automation

    • Delay: OFF ≤20.5 ms; ON ≤100 µs

  • Trigger Inputs: 2 channels, Sink type, 24 VDC

    • Delay: Rising 52 µs ±0.5 µs; Falling 53 µs ±0.5 µs

  • Temperature Sensor Input: 1 channel (500 Ω–5 kΩ resistive)B& R Industrial Automation

  • Standby Power: 7.5 W

  • Discharge Capacitance: 0.14 µFB& R Industrial Automation

4. Mechanical Specifications

  • Dimensions (W × H × D): 53 mm × 317 mm × 263 mm (wall mount)B& R Industrial Automation

  • Weight: Approx. 2.9 kgB& R Industrial Automation

  • Protection Class: IP20 (EN 60529)

  • Pollution Degree: 2 (non‑conductive)

  • Overvoltage Category: III (EN 61800-5-1)

5. Environmental Conditions

5.1 Temperature

  • Operating: 5–40°C (rated); up to 55°C (with derating)B& R Industrial Automation

  • Storage: −25–55°CB& R Industrial Automation

  • Transport: −25–70°CB& R Industrial Automation

5.2 Humidity

  • Operating: 5%–85% RH (non‑condensing)B& R Industrial Automation

  • Storage: 5%–95% RH (non‑condensing)B& R Industrial Automation

  • Transport: Max 95% RH at 40°C (non‑condensing)B& R Industrial Automation

5.3 Mounting & Altitude

  • Allowed Orientation: Vertical hanging, horizontal face‑upB& R Industrial Automation

  • Forbidden: Horizontal side mountingB& R Industrial Automation

  • Rated Altitude: 0–500 mB& R Industrial Automation

  • Max Altitude: 4000 m (with derating)B& R Industrial Automation

6. Interface & Terminal Assignment

  • X1 (Control): Enable, brake, and digital signal terminals

  • X2 (24 VDC): Auxiliary power input and output

  • X3 (Encoder): Plug‑in module interface (e.g., EnDat, HIPERFACE)

  • X4 (Brake/Temp): Motor brake and temperature sensor connection

  • X5 (Motor Power): U/V/W/PE; 0.25–6 mm² wire range

7. LED Status Indicators

  • RDY (Green): Module ready; flashes if not ready (undervoltage, overtemperature)

  • RUN (Orange): Power stage enabled, axis active

  • ERR (Red): Fault (overload, short circuit, overtemp)

  • POWERLINK: Link/activity status

  • 24V (Green): Auxiliary power normal

8. Protection & Safety Functions

  • Motor Protection: Overload, short circuit, earth fault

  • Thermal Protection: IGBT/heat sink overtemperature; motor temp monitoring

  • Voltage Protection: DC bus over/undervoltage; 24 VDC undervoltage

  • Safety: Integrated Safe Stop, safe standstill (compliant with EN 61800-5-2)

  • Brake Protection: Overload, open/short circuit, undervoltage detection

9. Accessories

9.1 Mandatory

  • Terminal Block Set: 8BZVI0110S0.000-1A

9.2 Optional

  • Plug‑in Modules: EnDat 2.2 (8BAC0120.001-2), HIPERFACE (8BAC0121.000-1), resolver (8BAC0122.000-1), etc.

  • Fan Module: 8BXF001.0000-00

  • Shield Kits: 8SCS000.0000-00, 8SCS002.0000-00

  • Cables: POWERLINK/Ethernet (X20CA0E61.00020–X20CA0E61.00100)

10. Typical Applications

  • CNC machine tools and machining centers

  • Automated assembly and production lines

  • Packaging, printing, and textile machinery

  • Logistics positioning and conveying systems

  • High‑precision single‑axis motion control


Get a Quote